Assembly and settings
Item Mounting
JGP-P
40
50
64
80
100
1
Thread in the main air
connections
M3
M5
M5
M5
G1/8
Max. depth of engagement
from locating surface [mm]
4
5
6
6
7
2
Thread in the air purge
connection
M3
M3
M5
M5
M5
Max. depth of engagement
from locating surface [mm]
3.9
5
6
6
6
Item Mounting
JGP-P
125
160
200
240
300
1
Thread in the main air
connections
G1/8 G1/8 G1/8 G1/8 G1/4
Max. depth of engagement
from locating surface [mm]
7
7
7
7
12
2
Thread in the air purge
connection
M5
M5
M5
M5
M5
Max. depth of engagement
from locating surface [mm]
6
6
6
6
6
Air purge connection
The air purge is used in order to make it more difficult for dirt and
dust to penetrate into the product and the guiding areas.