Maintenance
1. Remove set-screw on an air purge connection (1).
2. Screw in lubrication nipple.
3. Apply a layer of grease to metallic sliding surfaces of the
gripper using the lubrication nipple,
.
✓
While lubricating, completely open and close the gripper
alternately.
4. Unscrew the lubrication nipple.
5. Screw set-screws into both air purge connections (1).
7.5 Replace seals
7.5.1 Replace seal (variant without gripping force maintenance)
1. Remove all compressed air lines,
2. Remove product from the system/machine.
3. Remove the cover (10).
4. Mark the installation position of the base jaws (3) on the
housing (2).
5. Remove the screws and the cover (4).
6. Unscrew screw (6) and take cylinder piston (8) out of the
housing (2).
7. Push the wedge hook (1) out of the housing (2).
8. Take base jaws (3) out of the housing (2).
9. Remove old seals (9, 5 and 7).
10. Clean guiding areas.
11. Mount new seals (9 and 7) from the seal kit.
12. Re-lubricating guiding areas
13. Insert base jaws (3) into the housing (2).
IMPORTANT! Observe
installation position of the base jaws (3) in the housing (2).
14. Insert wedge hook (1) into the housing (2).
51