Assembly and settings
5.4.2 Setting dimensions for magnetic switches
* Setting dimension I1, from product bottom edge (1) to front sensor (2)
The setting dimension applies for the following sensors:
• Programmable magnetic switch MMS 22-PI2
• Programmable magnetic switch MMS-P 22
• Programmable magnetic switch MMS 22-PI1
• Analog magnetic switch MMS 22-A
Size
l1* [mm] Size
l1* [mm]
40
11.9
100
27
40 AS
11.9
100 AS
27
40 IS
21.9
100 IS
53
50
22
125
30
50 AS
22
125 AS
30
50 IS
38
125 IS
60
64
17.8
160
38
64 AS
17.8
160 AS
33.5
64 IS
35.8
160 IS
78.5
80
25.8
200
40.5
80 AS
25.8
200 AS
34
80 IS
43.8
200 IS
92.2
NOTE
The magnetic switch MMS 22-PI1 can be adjusted and taught in
two ways.
• "Standard mode" allows for quick installation on the T-nut
preset by SCHUNK in the groove or the defined setting
dimension "l1."
• In "Optimal Mode", the sensor identifies the optimal position in
the groove itself.
SCHUNK recommends "Optimal Mode" for setting the sensors.
Further information on the installation of the
sensor,
31
02.00 | JGP-P | Assembly and Operating Manual | en | 1469637