Assembly
82
05.00 | ERT 12 / 50 / 300 | Translation of Original Operating Manual | en | GAS0406665
1. Loosen the screws (1) and remove.
2. Remove seal mount (2), O-ring (4) and sealing ring (3).
NOTE
Thoroughly clean seal mount (2) and seal surfaces in the housing.
3. Lubricate O-ring (4) and sealing ring (3) with prescribed grease
on the inner and outer diameter.
4. Place the sealing ring (3) in the seal mount (2).
NOTE
The notch of the sealing ring (3) must point in the direction of
the arrow (A).
5. Insert the seal mount (2) into the housing.
6. Tighten the screws (1).
✔
Tightening torque: 1.2 Nm