Possible malfunctions in the overall system
01.00|Ident-Nr. 1494155|en
63
Tablet will not charge
Dirty charging contact of
tablet, USB power plug or
charging cable
Clean charging contact
and check for function
Power socket has no voltage Check power socket
Plug connection, loose USB
cable Check plug
connections
Charger damaged
Send device to SCHUNK
8.1.1
Possible faults with the iTENDO
Malfunction / occuring
error
Possible reason
Measures to resolve
Tool is not sufficiently
clamped in the tool holder
Shaft does not correspond
the requirements
Check shaft and measure
actual diameter
Clamping screw is not
actuated to its full block
Screw in the clamping screw
completely
Tool holder cannot be
clamped in the machine
spindle
Damaged tool holder
Check the tool holder
Interface of tool holder and
machine spindle do not fit
together
Check according to the
technical data
Dirty interface of tool holder Clean interface