Maintenance
32
04.00 | FDB | Assembly and Operating Manual | en | 389072
8 Maintenance
The user is encouraged to return the unit to SCHUNK for
maintenance.
is provided to assist the user when they
choose to maintenance the FDB in the field. For all maintenance, it
is recommended that the air supply (before the solenoid valves) be
disconnected. Drain any trapped air pressure in the lines. It is
suggested that the air supply be “locked out” to prevent accidental
operation of the spindle. During maintenance operations, refer
to
Procedures for maintenance instructions. Service
and repair parts are identified in Serviceable Parts.
8.1 Recommended Spare Parts
For repair and spare parts please contact SCHUNK. Suggested user
replaceable, optional and spare parts are listed in the tables
below. All other repairs must be performed by SCHUNK:
Available spare parts
FDB-150
1/8" collet
3 mm collet
Clamping nut
Replacement motor
FDB-300/-340
Ø 3 mm collet
Ø 1/8” collet
Ø 3/16” collet
Ø 6 mm collet
Ø 1/4” collet
Clamping nut, FDB 300/ FDB 340 motor (.450 Lg. x .318 hole)
Clamping nut, FDB 300/ FDB 340 motor (.450 Lg. x .254 hole)
Spindle hose adapter, 3/8 to 5/16" [8 mm]
Spindle hose adapter, 1/2" to 5/16" [8 mm]
Replacement motor
FDB-900/1040
Ø 4 mm ER-11 collet
Ø 6 mm 1/4” ER-11 collet
Clamping nut, ER collet
Replacement motor
Recommended parts
for stocking
SCHUNK recommends stocking the following spare parts:
FDB-150
Collar
Replacement motor