Installation
Air line fittings supplying the FDB should be installed with care
using a minimum of tape or liquid sealant. To prevent contaminant
damage to the air motor, all air lines should be blown down to
remove debris prior to connection of the FDB.
CAUTION
The FDB must be supplied with clean, dry, non-lubricated air
filtered five micron or better. The use of a coalescing filter is
recommended.
Water and oil damage of the air motor or damage associated
with the debris in the air lines is not covered under warranty.
5.3.1 Axial Mounting Installation
Clamping Collar
Blank
Interface Plate
Clamping Collar
(2x) M5 Socket Head Cap Screws
Axial Mounting Flange on rear Housing Assembly
Axial Installation
A blank robot adapter plate is also available to allow axial
mounting off the rear of the deburring tool housing. This plate
may be modified by the system integrator or by the owner/user of
the FDB. SCHUINK can provide custom interface plates and
adapters upon request. An optional bench mount adapter plate
allows the FDB to be permanently attached to a bench or other
work surface . If the FDB is permanently mounted to a work
surface, the robot carries the part to be deburred to the FDB.
17
04.00 | FDB | Assembly and Operating Manual | en | 389072