background image

 

6

 

7.  CHARGING THE INTERNAL BATTERY OF THE INSTANT POWER

IMPORTANT: CHARGE IMMEDIATELY 

AFTER PURCHASE, AFTER EACH USE  

AND EVERY 30 DAYS TO KEEP 

THE INSTANT POWER’S INTERNAL 

BATTERY FULLY CHARGED. 

7.1 

Use of an improper extension cord to 

charge the Instant Power could result in a 

risk of fire and electric shock. Make sure:

• 

That the pins on the plug of the extension 

cord are the same number, size and shape 

as those of the plug on the Instant Power.

• 

That the extension cord is properly wired 

and in good electrical condition.

• 

That the extension cord has a wire size of 

18 gauge (AWG) [0.82 mm

2

] or larger and 

is 50 feet (15.24 meters) long or less.

7.2 

To reduce the risk of electric shock, turn 

off and/or unplug the Instant Power before 

attempting any maintenance or cleaning. 

Simply turning off the controls will not 

reduce this risk.

7.3 

When charging the internal battery, work 

in a well-ventilated area and do not 

restrict the ventilation in any way.

7.4  LED Indicators:

To check the internal battery’s charge 

status, press the 

Battery Status

 button 

on the front of the Instant Power.

The 

LED

 lights will indicate the charge 

level as follows:

 RED –

 less than 20% of full charge;  

  immediately charge the unit.

 YELLOW/ORANGE –

 20-80% of full  

 charge. 

 GREEN –

 more than 80% of full charge.

7.5  Charging the internal battery

Charge the internal battery for the  

Instant Power using an extension cord  

(not included).

NOTE:

 Use of an improper extension cord 

may result in a risk of fire and electric 

shock. 

1. 

To charge, plug an 18 gauge (AWG) or 

larger extension cord into the charger 

plug on the right side of the Instant 

Power.

2. 

Plug the extension cord into a 120VAC 

electrical wall outlet.

3. 

While the jump starter is charging, the 

RED   LED

 will be on. Complete 

charging may take up to 72 hours. 

When the 

RED LED

 turns off, the jump 

starter is ready to use.

4. 

When the internal battery is fully 

charged, the charger will automatically 

go into maintain mode and maintain 

the battery at full charge without 

damaging it. When in maintain mode, 

the 

GREEN   LED will pulse

, as 

long as there is an AC cord connected 

to the charging port.

5. 

Charge the Instant Power as soon as 

possible after use.

7.6  Charging the internal battery while 

driving

You may also charge the internal battery 

while driving, using a male-to-male 

charger cable (part number 94500109 – 

not included). 

IMPORTANT:

 DO NOT CHARGE 

INTERNAL BATTERY FOR MORE THAN 

30 MINUTES OR LEAVE THE BATTERY 

UNATTENDED. IT COULD EXPLODE, 

CAUSING PROPERTY DAMAGE OR 

PERSONAL INJURY. 

1. 

Make sure the car is running.

2. 

Insert one end of the accessory cable 

into the 12V DC power outlet. 

3. 

Insert the other end of the accessory 

cable into the vehicle’s accessory 

outlet (lighter socket). 

NOTE: 

The 

RED LED

 does not operate 

during this method of charging. Using this 

method to charge the battery overrides 

the maintain mode and the battery can be 

overcharged. 

4. 

Monitor the progress of the charge by 

pressing the 

Battery Status

 button 

on the front of the unit. When the 

battery is fully charged, disconnect 

the accessory cable from the Instant 

Power, then from the lighter socket of 

the vehicle. 

NOTE:

 Completely disconnect the charger 

cable when the engine is not running. 

Содержание INSTANT POWER IP-95C

Страница 1: ...ese instructions and precautions carefully POR FAVOR GUARDE ESTE MANUAL DEL PROPIETARIO Y LEER ANTES DE CADA USO En este manual se explica c mo utilizar el Instant Power segura y efectiva Por favor le...

Страница 2: ...s y ceguera Mant ngase alejado de los ni os AVERTISSEMENT Hasard d explosion possible Contact avec l acide de batterie peut provoquer s v re br le et la c cit Ne le laissez pas a la port e des enfants...

Страница 3: ...R A REPARACIONES 18 ESPECIFICACIONES 18 REPUESTOS ACCESORIOS 18 GARANT A LIMITADA 18 WARRANTY CARD TARJETA DE GARANT A 27 TABLE DES MATI RES CONSIGNES DE S CURIT IMPORTANTES 19 PR CAUTIONS PERSONNELLE...

Страница 4: ...any equipment you intend to use in the vicinity of the battery Review the cautionary markings on these products and on the engine 1 12 This Instant Power employs parts such as circuit breakers that te...

Страница 5: ...at the Instant Power cable clips make tight connections 4 INSTANT POWER LOCATION WARNING RISK OF EXPLOSION AND CONTACT WITH BATTERY ACID 4 1 Locate the Instant Power as far away from the battery as th...

Страница 6: ...charge plug an 18 gauge AWG or larger extension cord into the charger plug on the right side of the Instant Power 2 Plug the extension cord into a 120VAC electrical wall outlet 3 While the jump start...

Страница 7: ...l lines or sheet metal body parts Connect to a heavy gauge metal part of the frame or engine block IMPORTANT If you have connected the clips backward an audio alarm will sound DO NOT turn the ON OFF s...

Страница 8: ...6 Recharge the unit before storing NOTE To prevent overheating the compressor has built in thermal protection that will turn the compressor off before it overheats If the compressor shuts off wait a...

Страница 9: ...t the Instant Power and reverse the clamps Press the Battery Status button on the front of the unit The LEDs will indicate the status of charge Have the battery checked The Instant Power won t power m...

Страница 10: ...and approved for use with this product This Limited Warranty is void if the product is misused subjected to careless handling repaired or modified by anyone other than Manufacturer or if this unit is...

Страница 11: ...ES EXPLOSIVOS DURANTE SU NORMAL FUNCIONAMIENTO POR ESTE MOTIVO RESULTA DE SUMA IMPORTANCIA QUE SIGA LAS INSTRUCCIONES CADA VEZ QUE UTILIZA EL INSTANT POWER 1 11 Para reducir el riesgo de explosi n de...

Страница 12: ...da mientras que el Instant Power se est utilizando 3 2 Limpie los terminales de la bater a antes de usar el Instant Power Durante la limpieza evite que la corrosi n producida por aire tenga contacto c...

Страница 13: ...ER PORTATIL CARGADA COMPLETAMENTE 7 1 El uso de un alargador inadecuado puede provocar riesgo de incendio o descarga el ctrica Cuando se use una extensi n aseg rese de que Los pasadores en el enchufe...

Страница 14: ...LES O LESIONES CORPORALES 1 Aseg rese de que el veh culo est en marcha 2 Inserte un extremo del cable auxiliar en la toma de corriente de 12 V CC 3 Inserte el otro extremo del cable auxiliar en el enc...

Страница 15: ...na fuente de poder para cualquier accesorio de 12V de corriente directa que est n equipados con enchufe de 12V Util celo durante apagones pesca o d as de campo Tiempos estimados se muestran en el gr f...

Страница 16: ...esta dise ado para 150 PSI Tiempo estimado para inflar Neum ticos para veh culos de 13 a 16 6 a 24 minutos Llantas para bicicleta 1 a 3 minutos Balones deportivos 30 segundos Estos valores son aproxi...

Страница 17: ...existe buena conexi n a la bater a y la carrocer a Tambi n que los puntos de las conexiones est n limpios Gire las pinzas para una conexi n efectiva Desconecte la fuente de poder y coloque las pinzas...

Страница 18: ...es autorizados para que estos reparen o reemplacen el producto El Fabricante no presta garant a por lo accesorios utilizados con este producto que no sean los fabricados por Schumacher Electric Corpor...

Страница 19: ...INSTANT POWER 1 11 Pour r duire le risque d explosion de la batterie suivez ces directives et celles publi es par le fabricant de la batterie et du fabricant de tout autre appareil que vous pensez ut...

Страница 20: ...vant d utilis e l unit Lors du nettoyage ne laissez pas les particules de corrosion entrer en contact avec vos yeux votre nez et votre bouche Utilisez du bicarbonate de sodium et de l eau pour neutral...

Страница 21: ...ue Que les broches sur la prise de la rallonge sont du m me nombre de la m me taille et forme que celles de la prise du Instant Power Que la rallonge est bien c bl e et en bonne condition lectrique Qu...

Страница 22: ...de l unit Quand il atteint une charge compl te d branchez le c ble accessoire de l unit puis partir de l allume cigare du v hicule REMARQUE D branchez compl tement le cordon du chargeur lorsque le mot...

Страница 23: ...ont fix es sur les supports de stockage 3 Ouvrez le couvercle de protection de la prise d alimentation CC 4 Branchez l appareil 12V CC dans la prise d alimentation CC et allumez l appareil 12V CC si n...

Страница 24: ...en d branchez et d connectez le Instant Power voir les sections 3 et 4 9 2 Utilisez un chiffon sec pour nettoyer toute corrosion de la batterie ainsi que la salet ou l huile sur les broches les c bles...

Страница 25: ...e produit de 12V Le disjoncteur interne se r initialise automatiquement apr s une minute ou deux Essayez nouveau l appareil 12V La batterie interne ne garde pas la charge La batterie est d fectueuse n...

Страница 26: ...it est mal utilis soumis une manipulation imprudente r par ou modifi par une personne autre que le fabricant ou si cet appareil est revendu par un d taillant non autoris Le fabricant ne fait aucune au...

Страница 27: ...___________________ Esta es la nica garant a limitada expresa y el productor no autoriza ni otorga a alguien a realizar alguna otra obligaci n No existe ninguna otra garant a m s que la descrita en el...

Страница 28: ...RIGINAL puisqu il sera requis pour une ventuelle r clamation au titre de la garantie Cette garantie n est pas transf rable Envoyer la carte de garantie seulement NE PAS ENVOYER L UNIT CETTE ADRESSE PO...

Отзывы: