Page 74 of 173
Version: 57E
4.3.4.2.5
Dual-channel output with relay output and semiconductor output
–
external control
circuit with monitoring
For safety applications from PL d and higher according to EN ISO 13849-1. The external circuit is
operated using two channels via one relay output and one semiconductor output. Each of the two
external shutdown paths is monitored. An adequately high test rate as well as MTTF
D
= high for the
external circuit are required for PL e according to EN ISO 13849-1.
Q0_P
X21
X12
Q1_N
Q2_P
Q3_N
Q4.1
Q4.2
Q5.1
Q5.2
X22
I12
I13
T0
T1
P
N
L +
L -
Dual-channel output with relay output and semiconductor output
–
external control circuit with monitoring
4.3.4.2.6
Dual-channel output with relay output - external control circuit in PL e
For safety applications from PL d and higher according to EN ISO 13849-1. The external circuit is
operated using two channels via the relay outputs. An adequately high test rate as well as PL e for the
external circuit are required for PL e according to EN ISO 13849-1.
L +
L -
Q4.1
X22
Q4.2
Q5.1
Q5.2
STO
Pl e
Dual-channel output with relay output - external control circuit in PL e
Содержание PSC1-C-10 Series
Страница 1: ...Installation manual for PSC1 modules Series PSC1 C 10 PSC1 C 10 SDMx PSC1 E 3x...
Страница 98: ...Installation manual PSC1 C 10 Installation manual V2 6 Page 98 of 173 Version 57E 2 I 09 3 I 10 4 I 11...
Страница 140: ...Installation manual PSC1 C 10 Installation manual V2 6 Page 140 of 173 Version 57E...
Страница 153: ...Installation manual PSC1 C 10 Installation manual V2 6 Page 153 of 173 Version 57E Example for a hazard analysis...