Example software specification
Seq.
no.
Safety function
PLr
Measured value
/sensor
New solution
Input/activation
Response/output
1.4
Monitoring V_rope in
relation to V_required
Monitoring of the difference
between main drive speed
and rope drive for maximum
value
d
Digital
incremental
encoder,
tacho generator
sheave
Monitoring using tested function SLS +
SAC with comparison of speed ranges /
analogue value range = comparison for
diagnostics on the speed acquisition
Shutdown 2-channel new (see below)
Continuous
Reset:
Reset button
Operating stop
SF 1.3.1
1.6
Backstop
Monitoring for return
d
Mechanical limit
switch 22S2
Digital
incremental
encoder
Monitoring using tested function,
direction monitoring SDI
NOT (auxiliary contact
28K4
–
inspection
movement)
Reset:
Reset button
Operating stop
SF 1.3.1
1.15
Stepwise shutdown 3
Activation of the safety
brake
e
-
Processing of SF in SafePLC2
SF 1.2
SF 1.3.2
SF 1.7
SF 1.8
Set safety brake
1.8
Functional standstill
d
Digital
incremental
encoder
Standstill monitoring using tested
function SOS
Controller disable
OR
Set service brake
SF 1.15/
Set safety brake
1.9
Direction monitoring
e
Digital
incremental
encoder,
Monitoring using tested function,
direction monitoring SDI
28K1 = FORWARD
28K2 = BACK
Operating stop
SF 1.3.1
Содержание PSC1-C-10 Series
Страница 1: ...Installation manual for PSC1 modules Series PSC1 C 10 PSC1 C 10 SDMx PSC1 E 3x...
Страница 98: ...Installation manual PSC1 C 10 Installation manual V2 6 Page 98 of 173 Version 57E 2 I 09 3 I 10 4 I 11...
Страница 140: ...Installation manual PSC1 C 10 Installation manual V2 6 Page 140 of 173 Version 57E...
Страница 153: ...Installation manual PSC1 C 10 Installation manual V2 6 Page 153 of 173 Version 57E Example for a hazard analysis...