Maintenance
EN-US · 30.30.01.01598 · 02 · 01/18
67 / 74
10 Maintenance
10.1 Safety
Maintenance work may only be carried out by qualified personnel.
WARNING
Risk of injury due to incorrect maintenance or troubleshooting
4
Check the proper functioning of the product, especially the safety features, after every
maintenance or troubleshooting operation.
CAUTION
Damage due to flying parts
Risk of injury or damage to property!
4
Wear eye protection
4
Before performing maintenance, make sure that the vacuum and compressed air sys-
tem is at atmospheric pressure.
NOTE
Improper maintenance
Damage to the compact terminal and the ejectors!
4
Switch off the supply voltage before any maintenance.
4
Secure it so that it cannot be switched back on.
4
The compact terminal must only be operated with a silencer and press-in screens.
10.2 Replacing the Silencer
When the silencer is open, a heavy infiltration of dust, oil, and so on, may contaminate it and reduce the
suction capacity. We do not recommend cleaning the silencer because of capillary action in the porous
material.
4
If the suction capacity decreases, replace the silencer.
10.3 Replacing the Press-In Screens
The vacuum and compressed air connections of the ejectors contain press-in screens. Dust, chippings and
other solid materials may be deposited in the screens over time.
4
If you notice that the performance of the ejectors has declined, replace the screens.
10.4 Cleaning the Compact Terminal
1. For cleaning, do not use aggressive cleaning agents such as industrial alcohol, white spirit or thin-
ners. Only use cleaning agents with pH 7–12.
2. Remove dirt on the exterior of the device with a soft cloth and soap suds at a maximum tempera-
ture of 60° C. Make sure that the compact terminal is not soaked in soapy water.
3. Ensure that no moisture gets into the electrical connection.
Содержание SCPSt 07 G02 NC
Страница 72: ......
Страница 73: ...30 30 01 01598 02 01 19 73 74 ...
Страница 74: ... J Schmalz GmbH EN US 30 30 01 01598 02 01 18 Subject to technical changes without notice ...