![Schmalz SCPSt 07 G02 NC Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/schmalz/scpst-07-g02-nc/scpst-07-g02-nc_operating-instructions-manual_1212957038.webp)
Interfaces
38 / 74
EN-US · 30.30.01.01598 · 02 · 01/18
Hysteresis Setting h2 for the Ejectors
Parameter
103 (0x0067)
Description
Hysteresis h2 for ejectors
Index
Index 0 to 15 corresponds to ejector #1 to #16
Data type
uint16
Length
32 bytes
Access
Read/Write
Value range
(H2-2) >= h2 >= 10
Default value
10
Unit
mbar
EEPROM
Yes
Blow Off Time of the Ejectors
Parameter
106 (0x006A)
Description
Duration of automatic blow for ejectors
Index
Index 0 to 15 corresponds to ejector #1 to #16
Data type
uint16
Length
32 bytes
Access
Read/Write
Value range
0 to 9999
Default value
200
Unit
ms
EEPROM
Yes
Evacuation Time Limit for the Ejectors
Parameter
107 (0x006B)
Description
Permissible evacuation time t1 for ejectors
Index
Index 0 to 15 corresponds to ejector #1 to #16
Data type
uint16
Length
32 bytes
Access
Read/Write
Value range
0 to 9999
Default value
2000
Unit
ms
EEPROM
Yes
Leakage Limit for the Ejectors
Parameter
108 (0x006C)
Description
Permissible leakage rate for ejectors
Index
Index 0 to 15 corresponds to ejector #1 to #16
Data type
uint16
Length
32 bytes
Access
Read/Write
Содержание SCPSt 07 G02 NC
Страница 72: ......
Страница 73: ...30 30 01 01598 02 01 19 73 74 ...
Страница 74: ... J Schmalz GmbH EN US 30 30 01 01598 02 01 18 Subject to technical changes without notice ...