![Schmalz SCPSt 07 G02 NC Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/schmalz/scpst-07-g02-nc/scpst-07-g02-nc_operating-instructions-manual_1212957041.webp)
Interfaces
EN-US · 30.30.01.01598 · 02 · 01/18
41 / 74
Air Consumption of the Ejectors
Parameter
156 (0x009C)
Description
Air consumption per cycle for ejectors
Index
0 to 15: Air consumption per cycle for ejectors #1 to #16
16: Air consumption per cycle of all ejectors
Data type
uint32
Length
68 bytes
Access
Read only
Value range
0 to 15: 0 to 65535
16: 0 to 1048560
Default value
-
Unit
0.1 Nl
EEPROM
no
Leakage Rate of the Ejectors
Parameter
160 (0x00A0)
Description
Leakage rate for ejectors
Index
Index 0 to 15 corresponds to ejector #1 to #16
Data type
uint16
Length
32 bytes
Access
Read only
Value range
0 to 8000
Default value
-
Unit
mbar/s
EEPROM
no
Dynamic Pressure of the Ejectors
Parameter
161 (0x00A1)
Description
Free-flow vacuum for ejectors
Index
Index 0 to 15 corresponds to ejector #1 to #16
Data type
uint16
Length
32 bytes
Access
Read only
Value range
0 to 999
Default value
-
Unit
mbar
EEPROM
no
Maximum Vacuum of the Ejectors
Parameter
164 (0x00A4)
Description
Max. vacuum reached in cycle for ejector
Index
Index 0 to 15 corresponds to ejector #1 to #16
Data type
uint16
Содержание SCPSt 07 G02 NC