Technical Data
EN-US · 30.30.01.01598 · 02 · 01/18
21 / 74
Type
1)
H2
H3
H4
d
X1
Y1
G1
G2
G3
m(g)
2
SCTMi (2)
89
54
22.5
5.5
108
64
G1/8-IG
G1/4-IG
M12x1-AG
700
SCTMi (3)
89
54
22.5
5.5
125
64
G1/8-IG
G1/4-IG
M12x1-AG
910
SCTMi (4)
89
54
22.5
5.5
143
64
G1/8-IG
G1/4-IG
M12x1-AG
1120
SCTMi (5)
89
54
22.5
5.5
162
64
G1/8-IG
G1/4-IG
M12x1-AG
1330
SCTMi (6)
89
54
22.5
5.5
180
64
G1/8-IG
G1/4-IG
M12x1-AG
1540
SCTMi (7)
89
54
22.5
5.5
199
64
G1/8-IG
G1/4-IG
M12x1-AG
1750
SCTMi (8)
89
54
22.5
5.5
217
64
G1/8-IG
G1/4-IG
M12x1-AG
1960
SCTMi (9)
89
54
22.5
5.5
236
64
G1/8-IG
G1/4-IG
M12x1-AG
2170
SCTMi (10)
89
54
22.5
5.5
254
64
G1/8-IG
G1/4-IG
M12x1-AG
2380
SCTMi (11)
89
54
22.5
5.5
273
64
G1/8-IG
G1/4-IG
M12x1-AG
2590
SCTMi (12)
89
54
22.5
5.5
291
64
G1/8-IG
G1/4-IG
M12x1-AG
2800
SCTMi (13)
89
54
22.5
5.5
310
64
G1/8-IG
G1/4-IG
M12x1-AG
3010
SCTMi (14)
89
54
22.5
5.5
328
64
G1/8-IG
G1/4-IG
M12x1-AG
3220
SCTMi (15)
89
54
22.5
5.5
347
64
G1/8-IG
G1/4-IG
M12x1-AG
3430
SCTMi (16)
89
54
22.5
5.5
365
64
G1/8-IG
G1/4-IG
M12x1-AG
3640
All specifications are in mm
1)
(2 to 16) Digits correspond to the number of ejectors installed.
2)
With compressed air connection plate
4.3.3 Factory Settings
The factory settings relate to the particular SCTMi ejector.
Parameter
(dec)
(hex)
Value
Description
Limit value switching point H1
100
0x0064
-750 mbar
—
Hysteresis h1
101
0x0065
150 mbar
—
Limit value switching point H2
102
0x0066
-550 mbar
—
Hysteresis h2
103
0x0067
10 mbar
—
Blow-off pulse duration
106
0x006A
200 ms
—
Permitted evacuation time
107
0x006B
2000 ms
—
Permitted leakage
108
0x006C
250 mbar/s
—
Air saving function
109
0x006D
0x02
Control active
Blow-off mode
110
0x006E
0x00
Externally controlled
Содержание SCPSt 07 G02 NC
Страница 72: ......
Страница 73: ...30 30 01 01598 02 01 19 73 74 ...
Страница 74: ... J Schmalz GmbH EN US 30 30 01 01598 02 01 18 Subject to technical changes without notice ...