General Description of Functions
EN-US · 30.30.01.01602 · 01 · 10/18
21 / 58
5.3.4 Basic Menu
All of the settings for standard vacuum switch applications can be configured and read from the basic
menu.
1. Use
or
to select the desired adjustable parameter.
2. Confirm the selection of the parameter with the
button.
3. Use the
or
buttons to set the value of the parameter.
4. To save and exit the menu, press and hold the
button.
ð
The displayed value flashes to confirm.
Display code
Parameter
Explanation
5P1
or
FX1
Switching point 1 / upper window
point 1
—
rP1
or
FL1
Reset point 1 / lower window
point 1
—
hy1
or
-L-
Hysteresis switching point 1 (win-
dow mode) or leakage limit 1 (CM
mode)
—
5P2
or
FX2
Switching point 2 / upper window
point 2
—
rP2
or
FL2
Reset point 2 / lower window
point 2
—
hy2
or
L-2
Hysteresis switching point 2 (win-
dow mode) or leakage limit 2 (CM
mode)
—
tCX
Teach-in function
No
/
5P1
/
5P2
CAL
Calibrate zero offset
Calibrate integrated vacuum sensor,
No
/
yE5
EF
Additional functions
Menu: Additional functions
1mF
Information
Menu: Information
Overview of the display codes in the basic menu
Calibrating the vacuum sensor
1. Select the parameter or display code
CAL
with the
or
buttons.
2. Confirm using the
button.
3. Use the
or
buttons to select
YE5
.
4. Press the
button to confirm.
ð
The vacuum sensor integrated in the ejector is now calibrated.
Содержание SCPi FS RP
Страница 1: ...Compaktejector SCPi FS RP Operating Instructions WWW SCHMALZ COM EN US 30 30 01 01602 01 10 18...
Страница 17: ...Technical Data EN US 30 30 01 01602 01 10 18 17 58 4 4 4 Pneumatic Circuit Plan...
Страница 50: ......
Страница 57: ...Notes EN US 30 30 01 01602 01 10 18 57 58 16 Notes...
Страница 58: ...J Schmalz GmbH EN US 30 30 01 01602 01 10 18 Subject to technical changes without notice...