General Description of Functions
EN-US · 30.30.01.01602 · 01 · 10/18
19 / 58
5.3 Operating and Menu Concepts
The unit is operated via three buttons on the foil keypad. The parameters are set via software menus. The
current system status and the settings are shown on a display.
The operating structure is divided into three menus:
•
The basic menu
•
The menu for extended functions (EF)
•
The info menu (INF)
Setting of the vacuum switch in the basic menu is sufficient for standard applications. An extended func-
tions menu (EF) is available for applications with special requirements.
If settings are changed, undefined states of the system may occur for a short time (for approx. 50 ms).
The following information can be shown on the display:
•
The current vacuum measurement value
•
The selected menu item
•
The setting values
•
Error messages
In the basic operating menu state, the actual measurement value of the vacuum is displayed on the basis
of the chosen display unit. All units are available in millibar, kilo pascal, inch-hg and PSi. The measured
value is displayed as a positive compared to the ambient air pressure.
After setting a parameter via the operating menu, the power supply of the switch must remain
stable for at least 3 seconds, otherwise there may be a loss of data and the resulting error
E01
occurs.
The menus will automatically close if no button is pressed for 1 minute.
The display also returns to the basic status when an error status occurs so that the error number can be
displayed. A menu can be called up and used again afterward.
If parameters are changed using the IO-Link, the menu will also close. The instruction
dAt
will then ap-
pear on the display for 2 seconds.
5.3.1 Navigating in the Menu
The basic menu can be reached from the basic status by pressing the
DOWN BUTTON
or the
UP BUT-
TON
. Scrolling through the menu is also possible using these buttons. When the desired menu item
has been found, select it using the
MENU BUTTON
. If there is a submenu ("EF" and "INF"), this can
also be browsed in the same manner using the
DOWN
and
UP
buttons.
5.3.2 Enabling Vacuum Switches and Editing Parameters
Enabling Vacuum Switches
Using the Extended functions (EF) menu, the vacuum switch can be protected against unintentional access
by means of a PIN code
P1n
.
If you attempt to change a parameter value, the message "P.I.n" will appear in the display and changes to
enter the 3-digit PIN code. It is also possible to exit the menu in the meantime.
How to enable the vacuum switch:
1. Press the
button
ð
The display changes to input
2. Use the
or
buttons to enter the first digit of the PIN code
Содержание SCPi FS RP
Страница 1: ...Compaktejector SCPi FS RP Operating Instructions WWW SCHMALZ COM EN US 30 30 01 01602 01 10 18...
Страница 17: ...Technical Data EN US 30 30 01 01602 01 10 18 17 58 4 4 4 Pneumatic Circuit Plan...
Страница 50: ......
Страница 57: ...Notes EN US 30 30 01 01602 01 10 18 57 58 16 Notes...
Страница 58: ...J Schmalz GmbH EN US 30 30 01 01602 01 10 18 Subject to technical changes without notice...