SCHLAGEL, INC.
SCHLAGEL, INC.
EDI - V5 CONTROL
Page 9
CUSTOMIZING THE DISPLAY FORMAT
AND SPEED-DIAL KEYS
During the initial installation, default information is set so that the distributor can
be operated without further changes. However, most operators would like familiar
names and access codes assigned to each position of the distributor. The EDI-V5
control allows customization of Line1 and Line 3 using the control keypad to make
the changes.
Line 1
Line 2
Line 3
Line 4
In the examples above, the default O
PERATING
screen is shown on the left and a
fully modified display on the right. These changes are made using special 4-digit
access codes. The following changes were made to the default O
PERATING
screen:
Line 1
The caption on this line has been changed from “
SCHLAGEL, INC
.” to
“
RECEIVING LEG
”.
Line 2
This line is used for system alerts and information and cannot be modified.
Line 3
the access code <001> has been changed to <031>. This allows the operator
to move the distributor spout to this position by entering 31, a more logical choice
for accessing this position. Also, the name for the destination has been changed to
the more logical name.
Each distributor position can be individually programmed and displayed on this
line.
Line 4
This line is used for system status and keypad input and cannot be modified.
(*) RECEIVING LEG
<031> BIN 31
-* ->
(*) SCHLAGEL, INC.
<001> POSITION 1
-* ->