User Manual

3 MHz Function Generator/

Counter

S 5070/ SM5071

M

Содержание SM5070

Страница 1: ...User Manual 3 MHz Function Generator Counter S 5070 SM5071 M ...

Страница 2: ...rument contains proprietary information no part of this manual may be photocopied reproduced or translated without any prior written consent Information in this manual supercede all corresponding previous released material Scientific continues to improve products and reserves rights to amend part or all of the specifications procedures equipment at any time without notice Rev 2 2 0312 2 SM 070 SM5...

Страница 3: ...General Information 12 Safety 12 Operating Conditions 12 First Time Operation 13 Function Selection 13 Frequency Adjustment 13 OutputAmplitude Signal Connection 13 Trigger Output 14 Sweep Facilities 14 Internal Sweep 14 FM Input 14 DC Offset 15 Frequency counter SM5071 15 6 Maintenance 17 Power Line Fuse Replacement 17 7 Dispatch Procedure for Service 18 8 Warranty Conditions 19 9 List of Service ...

Страница 4: ...unction Generator Counter S 070 SM5071 M5 The various signals available from the Function Generator makes it a versatile signal source useful for most measurement and test applications Its low frequency ranges are particularly well suited for simulating mechanical and servo techniques Frequencies are read out on a with a maximum resolution of 1 mHz Additional quality features include the relativel...

Страница 5: ...0 1 to x1 10 1 0 5 h or 0 8 24 h at constant ambient temperature Medium position of frequency Control 0 3 Hz to 100 kHz max 0 5 0 1 MHz to 0 5 MHz max 1 5 0 5 MHz to 3 MHz max 3 Typ 40 ns 10 to 90 5 when output is terminated with 50 1 up to 100 kHz up to 3 Hz 1 3 digit 3 Hz to 3 MHz 5x10 1 Digit short circuit proof 10 Vpp into 50 max 20 Vpp open circuit Max 60 dB 2 steps 20 dB 0 2 dB each Variable...

Страница 6: ... Operating Conditions Dimensions mm Weight Accessories Connector on rear panel Approx 1 100 50 k 25pF 30 V max 20 ms to 4 s approx 1 100 10 Hz to 15 MHz 5x10 1D 50 mVrms 150 Vrms 1 M 50pF 16 2 dot matrix LCD display 230 V 10 50 Hz 22 VA approx 0 C to 50 C RH 95 max W 205 H 95 D 292 mm Approx 2 0 kg BNC BNC Values without tolerances are intended as guidelines and represent characteristics of the av...

Страница 7: ...7 SM5070 SM5071 User Manual 3 MHz FUNCTION GENERATOR COUNTER 5070 SM 3 3 4 2 14 15 13 12 6 5 8 7 10 11 9 Front Panel Controls S 5070 M ...

Страница 8: ...Front Panel Controls SM5071 8 SM 070 SM5071 U 5 ser Manual 3 MHz FUNCTION GENERATOR COUNTER SM5071 3 3 4 2 15 13 12 6 5 7 10 11 9 14 8 20 17 19 18 16 EXT IN FC LEVEL TRIG 1 10 ...

Страница 9: ...on switch Triangle Sine Square DC Setting of wobbulation speed in Sweep mode Activates the internal Sweep mode Setting of wobbulation width Activates the DC offset function When pressed the output signal gets attenuated by 20 dB fixed attenuator Short circuit proof signal output of the generator The output impedance is 50 600 and the max output amplitude is 20 V o c or 10 V respectively when termi...

Страница 10: ... the trigger level of counter can be adjusted with help of LEVELpotentiometer When pressed the input signal to frequency counter is attenuated 10 times LEVEL adjusting knob TRIG Push button 1 10 push button 10 SM 070 SM5071 U 5 ser Manual 18 19 20 ...

Страница 11: ...0 V AC 50 Hz 10 Spare fuse for mains is kept inside 11 SM5070 SM5071 User Manual Rear Panel Controls 21 24 22 23 SCIENTIFIC MES TECHNIK PVT LTD B 14 POLOGROUND INDUSTRIAL ESTATE INDORE 452015 INDIA SM5070 SM5071 Power 230V 50Hz Watts 22VA approx Fuse 0 15A timelag 5x20mm 24 23 TTL OUT FM IN Sr No XXXXXXXX 21 22 GND ...

Страница 12: ...transportation damage inform the supplier immediately and do not put the instrument into operation The case chassis and all measuring parts are connected to the protective earth contact of the inlet The mains plug shall only be inserted in a socket outlet provided with a protective earth contact The protective action must not be negated by the use of an extension cord without a protective conducto...

Страница 13: ...he LCD display Compared to knob scales this display has a much higher resolution and accuracy Adaptation in decade steps to the desired amplitude range is performed by the use of two attenuators with 20 dB each which are activated by push buttons Including the continuously adjustable AMPLITUDE control the maximum attenuation amounts to 60 dB With the maximum amplitude of 10V the minimum signal vol...

Страница 14: ...uit proof and can drive severalTTLinputs The internal sweep facility of the allows checking of filters and equipment in the frequency range from 0 3 Hz to 3 MHz Operation is very easy and is confined to the setting of sweep speed and sweep width Activation is by simply pressing the push button and can be combined with all available functions on the The Stop frequency is automatically given by the ...

Страница 15: ...function of the voltage and has the same value in all ranges This mode can be used in applications where the periodically required frequencies are to be set This will eliminate the repetitive setting of frequency from front panel via FREQUENCY set knob Such applications exists in production departments where signals at several specific frequencies are required for various tests FSK Frequency Shift...

Страница 16: ...gered externally by adjusting LEVEL Knob When instrument is triggered trigger LED is ON The input signal to frequency counter can be attenuated 10 times by pressing 1 10 Switch When switched ON the instrument works as a function generator By pressing FC Switch the instrument function as a Frequency Counter 16 SM 070 SM5071 U 5 ser Manual 20 9 18 10 ...

Страница 17: ...ing fluid should get into the instrument The use of cleaning agents can attack the plastic paint surfaces The power line fuse is located on rear panel on lower right side In case the instrument does not show any sign of working no LED is lit or there is no display immediately switch OFF the mains power switch of the instrument and unplug the mains cord from the mains socket With the help of small ...

Страница 18: ...ced 1 After receipt of your communication our service department will advise you whether it is necessary to send the instrument back to us for repairs or the adjustment is possible in your premises 2 Dispatch the instrument only on the receipt of our advise securely packed in original packing duly insured and freight paid along with accessories and a copy of the faults details noticed at our Servi...

Страница 19: ...mage caused by accident negligence mis application alteration or attempt to repair service or modify in any way 3 This warranty does not include LCD fuses batteries or accessories This warranty is only valid with the original purchaser who must have properly registered the product within 15 days from date of purchase No other warranty is expressed or implied 4 When it becomes necessary to return t...

Страница 20: ...hennai scientificindia com Indira Nagar Adyar Chennai 600 020 Scientific Mes Technik Pvt Ltd Ph 022 24211171 Room No 308 Building No 2 Fax 022 24333654 3rd Floor Sundar Nagar mumbai scientificindia com Co op Hsg Society Ltd Senapati Bapat Marg Dadar W Mumbai 400 028 Scientific Mes Technik Pvt Ltd Ph 020 26114688 209 Lloyd s Chamber III Fax 020 26132882 409 Mangalwar Peth pune scientificindia com M...