POWER
DIGITAL DISPLAY
Range :
FREQUENCY :
OFFSET :
AMPLITUDE :
FUNCTION :
SPEED :
SWEEP :
WIDTH :
OFFSET :
50 /600 :
-20 dB :
OUTPUT (BNC connector) :
-20 dB :
FC (Push button) :
EXT IN (BNC CONNECTOR) :
: Push button switch for supplying power to instrument.
: 16*2 dot matrix LCD display
Frequency range selection from 0.3 Hz to 3 MHz in 7decade steps
(adjusting knob) Continuous and linear frequency fine
adjustment, overlapping the ranges selected with
. Setting range from x0.09
to x 1.1 of the selected range.
Adjustment of the positive or negative offset voltage. DC voltage
can be superimposed on the output signal. The max. offset voltage is ± 5 V
(o.c.) or ± 2.5 V when terminated with 50
Continuous adjustment of the output amplitude from 0 to – 20
dB .
Mode selection switch (Triangle- Sine – Square – DC)
Setting of wobbulation speed in Sweep mode
Activates the internal Sweep mode
Setting of wobbulation width
Activates the DC offset function
When pressed the output signal gets attenuated by 20 dB fixed
attenuator.
Short-circuit-proof signal output of the generator.
The output impedance is 50
/600
, and the max. output amplitude is 20 V
(o.c.) or 10 V respectively when terminated with 50
When pressed the output signal gets attenuated by 20 dB fixed
attenuator. When both attenuator push buttons are activated, a total
attenuation of 40dB results. Including the amplitude control the max.
attenuation amounts to 60 dB (factor 1000).
When pressed instrument reads frequency of the input
connected on “EXT-IN
”
BNC connector.
Input to frequency counter. (max 15 MHz)
W.
W
W
W
W
W
Selects the output impedance at the output BNC
pp
pp
9