HOW TO USE OPTION CODES
Some accessories and operating functions of the EDI-V5 control require software
switches to be turned on or off. These switches are called Options and are made
accessible by the special access code 5996. To change an option, press 5996
Enter
at the
OPERATING
screen. The following example screen will appear.
The Ones and Zeros on Line 2 signify which of 16 option switches are on and
which are off. Starting from the left, Options 1-3 are on, 4-11 are off, 12 is on and
13-16 are off. Refer to the EDI-V5 OPTIONS chart on the next page to determine
the action for each switch.
As an example, option 16 turns the motor heater on or off. In the screen above it is
shown as being off. To turn it on, press 16
Enter
. The following screen then
appears showing the present status of this option and requests a 0 or 1 input to
change it, or
Enter
to leave it unchanged.
Press 1 (for on) and the first screen will re-appear, showing the change and
awaiting the selection of another option. Pressing
Enter
without entering a number
will return the control to the O
PERATING
screen.
Many of the options shown in the chart are used for enabling auxiliary devices to
the EDI-V5 control.
Most of these must be used with caution because they can
adversely affect reliable operation of the distributor.
Please contact our
technical support group if you are unsure of how to use these options.
See the chart on the following page for a complete list of options
.
MODIFY OPTIONS
1110000000010000
OPTION NBR TO CHANGE
-> _
MODIFY OPTIONS
1110000000010000
HEATER ON=0
0=Off, 1=On ->