Service Menu
38
The Calibrate command verify that the HandReader’s exposure values are within normal
operating parameters. The normal operating parameters are shown in Table 7.
Table 11-7: Normal Operating Parameters
Parameter
Normal Range
Row “r”
0 +/- 2
Column “c”
0 +/- 2
Exposure
100 +/- 20
The status display command allows you to enable or disable the displaying of the
following information.
•
the status values of HandReader inputs and outputs
•
the hand read score of the last user to verify on the HandReader
Figure 9-1 identifies each status display field value.
Last Hand Read Score
Aux Out 2
Aux Out 1
* Aux Out 0
* Lock
Aux In 2
Request to Exit
Aux In 1
Door Monitor Switch
Tamper
O = Circuit Open H = Output is OFF (High)
C = Circuit Closed L = Output is ON (Low)
- ENTER ID -
O C O C O H L H L NN
* These status values are
inactive if the reader is in Card
Reader Output Mode.
Figure 11-1: Status Display Chart
The network status command allows you to check the network communication status of
the HandReaders in the HandKey system.
You can check network status only from the Master HandReader in a master/remote
HandReader network.
Network status is displayed by reader address, 16 units at a time.
STAT: RDR 0-15
O O O O O O O O. . . . . . . .
Each “O” and “.” represents a HandReader address in the network. An “O” indicates that
the HandReader corresponding to that address is communicating on the network. A “.”
indicates that the HandReader with that address is not communicating on the network.
Calibrate
Status Display
Network Status
NOTE
!
Содержание HK-CR
Страница 1: ...HK CR Terminal User s Guide ...
Страница 18: ...This page intentionally blank ...
Страница 32: ...This page intentionally blank ...
Страница 34: ...This page intentionally blank ...
Страница 40: ...This page intentionally blank ...
Страница 48: ...This page intentionally blank ...
Страница 54: ...This page intentionally blank ...
Страница 60: ...This page intentionally blank ...
Страница 86: ...This page intentionally blank ...
Страница 87: ......