16
Anchor Plate
When commencing an installation with a fire chest, or when extending an existing
brick or masonry chimney stack, an anchor plate must be used. The liner of the
Anchor Plate should be pushed into the opening of the fire chest with the plate
resting on a bed of fire cement. The plate should then be fixed onto the concrete
slab by masonry screws fitted through the pre-drilled holes in the plate. In the case
of a chimney extension, the liner of the anchor plate fits down inside the existing
chimney stack, or if TecnoFlex Plus liner has been used, inside the chimney as a liner,
use the anchor plate with screw type connections. Refer Flexible Liners installation
instructions for more details. The plate should then be then be fixed to the top of
the existing chimney and sealed using fire cement.
Inspection Pipe with Test Point
The inspection length is a component providing the facility for flue inspection
and cleaning, including a test point. It is installed as per a standard pipe section.
Two versions available for Dry and Wet systems. The removable inspection door
must be parallel with the front of the stove, or at least 3 x the internal diameter
from any combustible material (125mm I/D door must be at least 450mm from
combustible material).
Adjustable Pipe/Telescopic Pipes
They are used with standard components to achieve an exact length on site and
avoid on-site cutting of components.
1. Calculate the length required.
2. Remove insulation as required to achieve the correct length.
3. Fix the adjusted section to standard components using the locking band provided.
Please note that the adjustable pipe is non load bearing.
When used in a condensing or a positive pressure application, the relevant gasket
kits must be applied by the installer (gaskets purchased separately). Follow Page 11
for instructions on Gasket Kits.
Adjustable
Pipe
(50-230mm)
Telescopic
Pipe
a) 215-310mm
b) 350-570mm
Anchor Plate
Inspection Length
(Dry Systems)
Effective
Length
302mm
Increaser
This component is used to increase from one diameter to the next diameter (e.g.) 125mm to 150mm. The component
is fitted in the same way as a standard pipe length and should be secured with the locking band provided.
90˚ Tee
Int Ø
Ext Ø
A
B
C
Int Ø
Ext Ø
90˚
90° Tee including Drain Cap
This component may be used to connect from a connecting flue pipe to the
vertical system chimney at 90° or the branch may be used to locate a draft
stabiliser. It is installed as per a standard pipe section. Please note that there are
no barbs on the female collar in order to allow for the tee to be positioned at the
correct angle. It is supplied complete with a locking plug.
Int Ø
Ext Ø
A
(mm)
B
(mm)
C
(mm)
100
150
282
150
120
200
256
394
195
170
125
180
301
154
133
150
200
329
162
142
180
235
354
176
160