Wall Band (50-90mm)
Internal and External Application
The wall band is supplied in two parts, a stainless steel bands which fits tightly around the outside of the chimney and a stainless steel back
bracket�
1� Once the position of the support has been determined, secure the back bracket to the wall with a method of fixing to ensure adequate
attachment and support�
2� The stainless steel band is then positioned around the chimney section and secured with the nut and bolt provided to the bracket�
3� The wall bracket provides lateral stability only, it is NOT load bearing and is to be positioned at 2 metre centres�
Adjustable Back Bracket (90-200/190-300/290-400mm)
Internal and External Application
The adjustable wall bracket is supplied in two parts, two stainless steel adjustable legs, and a frame which fits thightly around the outside of the
chimney�
1� Once the position of the support has been determined, secure the legs to the wall with a method of fixing to ensure adequate attachment and
support�
2� Determine the amount of extension required and secure the back bracket of the wall band in place onto the adjustable section�
3� Fasten the strengthening back frame in place using the bolts provided�
4� With the back frame in place, locate the rear portion of the band onto the back bracket, the outer part of the band is then positioned around
the chimney section and secure with the nuts and bolts provided�
5 The adjustable wall band provides lateral stability only, it is NOT load bearing and is to be positioned at 2 metre centres�
Adjustable Plate/band
The wall support is designed to be used internally or externally to provide either initial or intermediate support for the vertical chimney� It is used in combination with wall
brackets� The female socket on the pipe attached to the underside of the plate should be pushed down onto the preceding pipe and the joint secured using the locking band
provided� The top plate is then attached to the wall brackets using the bolts provided through the fixing slots in the top plate� The bolts should then be tightened firmly�
For maximum height of chimney see load bearing details, please refer to tables and diagrams on page 17�
Wall Brackets
Once the position of the support has been established in relation to the chimney route, secure wall brackets to the wall using expansion bolts to ensure adequate attachment
and support�
13
Metaloterm
®