background image

Wa l l   C h i m n e y   H o o d 

I n s t r u c t i o n   M a n u a l 

ZC622 ZC922

Contact Caple on 0117 938 7420 for spare parts or www.caple.co.uk

Содержание ZC622

Страница 1: ...Wall Chimney Hood Instruction Manual ZC622 ZC922 Contact Caple on 0117 938 7420 for spare parts or www caple co uk ...

Страница 2: ...ep this instruction manual for future reference C O NTE NT S Introduction 3 Safety Instructions 4 Environmental Protection 9 Installation 10 Operation 16 Care and Maintenance 17 Troubleshooting 19 Product Dimensions 20 Caple Contact Details 24 ...

Страница 3: ...th the appliance or visit www caple co uk and register here This instruction manual is designed to provide you with all the required information related to the installation use and maintenance of the appliance This hood is designed to extract unpleasant odours from the kitchen it is not intended to extract steam In order to operate the unit correctly and safely please read this instruction manual ...

Страница 4: ...t in fire electric shock or injury To protect against fire electrical shock and injury to persons do not immerse cords or plugs in water or any other liquid Never touch the appliance with wet or damp hands Never pull the power cable as you could damage it If the appliance is faulty do not attempt to repair it Isolate it from the mains electric supply and contact Caple Service either by phone 0117 ...

Страница 5: ... let children operate the machine The cooker hood is for home use only not suitable for barbecuing restaurants or other commercial purposes The cooker hood and its filter should be cleaned regularly in order to keep in good working condition Clean the cooker hood according to the instruction manual to reduce the risk of fire When using a gas hob do not leave naked flames under the extractor Before...

Страница 6: ...e air in the kitchen is being circulated before cooking commences and the air is being cleaned after cooking has finished The performance of your extractor will vary depending on a number of factors These include type of extraction room volume length of ducting ventilation available and the cleanliness of the filters This appliance is not intended for use by persons including children with reduced...

Страница 7: ...pe environments Bed and breakfast type environments To avoid all risk if the power cable is damaged it must only be replaced by a Caple appointed engineer Appliances can be used by persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazard...

Страница 8: ...ice from a suitably qualified engineer Failure to follow these instructions can result in death fire or electrical shock This appliance must be connected to the mains by a competent person We recommend that the appliance is connected by a qualified electrician who is a member of the N I C E I C who will comply with the I E E and local regulations Electrical information can be found on the rating p...

Страница 9: ...your local council your household waste disposal service or the retailer where you purchased the product WARRANTY Your new appliance is covered by warranty The warranty card is enclosed if it is missing you must provide the following information to your retailer in order to receive a replacement date of purchase model and serial number Registration can also be completed online by visiting www capl...

Страница 10: ...eter of 150mm Before installation turn the unit off and unplug it from the outlet The cooker hood should be placed at a minimum distance of 65 76cm above the hob It is the manufacturer of the hob who determines the clearance required and the clearance quoted by the hob manufacturer must be followed In the absence of any instructions supplied with a gas hob the minimum distance between the hob and ...

Страница 11: ... hood and appliance supplied with energy other than electricity are simultaneously in operation the negative pressure in the room must not exceed 4 Pa 4 10 5 Bar Drill 3 x 8mm holes to accommodate the bracket Screw and tighten the bracket onto the wall with the screws and screw plugs provided Level up the cooker hood and hang onto the wall bracket hook Wall Bracket Cooker Hood Screw Plug Wall Brac...

Страница 12: ...one way valve as shown below Instruction manual BXC611 BXC911 Please keep this instruction manual for future reference 12 Fix the one way valve to the air outlet of the cooker hood Then attach the exhaust pipe onto the one way valve as shown below 6 Exhaust pipe Cooker hood 6 xhaust pipe ker hood BXC611 _ BXC911 indd 12 18 05 2016 12 32 Secure the body with security screws Use 2 pcs ST4x30mm screw...

Страница 13: ...rill 2 holes to fix the lower chimney bracket with 2 wall plugs and 2 screws ST4x30mm Slide the chimney to adjust the chimney height When the height you require is reached mark and drill the fixing hole and fix the upper chimney bracket with 2 wall plugs and 2 ST4x30mm Fix the upper chimney with the upper chimney bracket using 2 scews ST4x8mm Lower Chimney Upper Chimney Wall Plug Plate Screw 4mm x...

Страница 14: ...ed INSTALLING THE CHARCOAL FILTER CAP61CF An activated charcoal filter can be used to trap odours In order to install the charcoal filter the grease filter should be detached first Press the release button and pull it downward as shown below Fit the activated charcoal filter onto the side of the motor and turn it in a clockwise direction to lock into place Repeat the same on the other side Scan th...

Страница 15: ...s R filters CAP61CF can be purchased directly from www ca NOTE Make sure the filter is securely locked Otherwise it may loosen and be dangerous When using a charcoal filter the extraction power may be slightly reduced We recommend replacing these filters every 6 months Replacement filters CAP61CF can be purchased directly from www caple co uk ...

Страница 16: ...change the speeds as per below Press again to switch off LOW SPEED BUTTON Is suitable for simmering and cooking which does not produce much steam or odour MEDIUM SPEED BUTTON Airflow speed is ideal for extracting with standard cooking HIGH SPEED BUTTON When a high amount of steam or odours are produced use the high speed setting for the most effective extraction LIGHT BUTTON Switches the light on ...

Страница 17: ...d the grease residue which is potentially flammable will saturate the filter It can be easily cleaned with warm water and washing up liquid alternatively the filters can be cleaned in your dishwasher Please ensure no other items are washed with the filters they must be washed separately to prevent food becoming trapped in the gauze Cleaning the grease filters in the dishwasher may lead to discolou...

Страница 18: ...placed by a qualified person 1 Switch the unit off and unplug the appliance 2 Unplug the LED lamp cable 3 Unscrew the screws and nuts on the 2 brackets 4 Replace the LED panel and screw back on to the brackets 5 Plug the LED lamp cable back in NOTE The LED light panel is for illumination of the cooking area only and not illuminating the room ...

Страница 19: ...e unit and contact Caple Service To be repaired by qualified service personnel only The fan motor is not fixed tightly Switch off the unit and contact Caple Service To be repaired by qualified service personnel only The unit is not hung correctly on the bracket Take down the unit and check whether the bracket is in the correct location The extraction performance is not good The filter requires cle...

Страница 20: ...Instruction manual ZC622 ZC922 20 Please keep this instruction manual for future reference PR OD UCT D IM ENSIONS ZC622 ZC922 D I M E N S I O N S 600 900mm 500mm 548 1000mm 60mm 320mm 280mm ...

Страница 21: ...Instruction manual ZC622 ZC922 21 Please keep this instruction manual for future reference ...

Страница 22: ...Instruction manual ZC622 ZC922 22 Please keep this instruction manual for future reference NOTES ...

Страница 23: ...Instruction manual ZC622 ZC922 23 Please keep this instruction manual for future reference NOTES ...

Страница 24: ...Caple Service Fourth Way Avonmouth Bristol BS11 8DW T 0117 938 1900 E service caple co uk www caple co uk ...

Отзывы: