heater to move®
warning and safety signs
•
Surrounding temperatures higher than 110°C (230°F) can cause damage to the electronics.
•
Never use or store the heater in areas of 110°C
(230°F)
or more.
NOTICE
Risk of malfunction or damage by heat exposure!
•
If the water freezes in the heat circuit or fresh water supply system, it can cause damage to the
equipment.
•
Make sure to have at least 20% of antifreeze mixed into the heating circuit water.
•
In risk of frost� drain the fresh water out of a heat system with plate heat exchanger.
NOTICE
Risk of malfunction or damage by frost!
general operating instructions
Note:
SCHEER cannot be held liable for:
•
Defects and damage� which are due to installation or repair by unauthorized and untrained persons.
•
Failure to comply with the instructions and the warning/safety signs.
•
The installation of non-original spare parts.
Please note the following general operating instructions after installing and during the use of the
MH-heating system:
•
The heating system
must be turned off before you get fuel
at gas stations.
•
The
year of the first start-up
must be permanently marked on the identification plate.
•
Make sure
all existing shut-off valves
of the fuel return line
are open
before using the system.
•
Check the openings of the combustion air supply and exhaust pipe
for dirt and
clean if necessary.
•
After replacing the vehicles cooling fluid
make sure to
bleed the system
of air thoroughly.
Add cooling
fluid
when needed.
•
After replacing the heating circuit water (solution)
make sure to
bleed the system
of air thoroughly.
Add solution
when needed.
(at least 20% antifreeze)
•
Make sure to
use the fuel and operation power indicated
on the identification plate.
•
In case of heavy smoke development, unusual burner noise, or smell of fuel, disable
the heating
system by
removing its fuse.
Operate the system only�
after a technical inspection
by a SHEER trained
person.
•
Turn on the heating system
at least once a month for 10 min..
•
The heating system must be checked
by a
SHEER trained person� before each heating season.
•
Liability claims can only be asserted,
if the claimant can prove adherence to the installation�
maintenance� and safety instructions.
8