www.scheer-heizsysteme.de
heater to move®
technical data boiler
* Calculated values for the design of the exhaust system in accordance with EN 13384 based on 13.2 % CO2 for EL
heating oil
** The guide values for sound pressure level measurements are not guaranteed values, as sound pressure level measu-
rements are always dependent on the respective system.
designation
unit
value
type
BE / SBN - 45 - MHF
t ype of fireplace
low-temperature boiler
fuel
fuel oil according to DIN 51603
nominal heat output
kW
19
CE-label
(according to oil equipment directive)
CE-0045CMKD 2340
Permissible flow temperature
(=safety temperature)
°C
95
Permissible operating pressure
bar
3
heating gas side resistance
mbar
0�30
heating gas side resistance hargeable resi-
dual conveying height
Pa
100
dimensions mm
(total dimensions)
see following drawing
total weight
(net)
Kg
110
Boiler water capacity
Liter
20
boiler connections
flow
Zoll/inch
1
return flow
Zoll/inch
1
exhaust gas characteristics
*
temperature (bei 60°C water temp.)
°C
193
exhaust gas volume flow
m
3
/h
27�5
exhaust gas connection
flue gas connection
Ø mm
50
sound pressure level
**
dB(A)
61
standard efficiency
%
94�4 (Hi)
Electric auxiliary heating
kW
max 3
5