Photocell
1
Press and hold SET until the operator displays ”P1”.
2
Press UP twice, the display shows “P3".
3
Press SET once again. Press UP once, it displays “H1”, the photocell is enabled. Press down
once, it displays “H0”, the photocell is disabled. Press SET to confirm selection.
4
If a photocell is not in use, be sure the display shows "H0" to disable this
function.
Auto-Close ON/OFF
1
Press and hold SET until the operator displays ”P1”.
2
Press UP three times, the display shows “P4”.
3
Press SET once again. Press UP to increase the auto-close one minute or press DOWN to
decrease one minute. Maximum setting is “b9” , minimum is “b0”. Press SET to confirm.
4
The default setting is “b0”, which means auto-close is off. This
function works when the door reaches the open position and only
works when a photocell is connected.
Motor opening force
1
Press and hold SET until the operator displays "P1".
2
Press UP four times, the display shows “P5”.
3
Press SET once again. Press UP to increase the force or press DOWN to
decrease the force. Press SET to confirm the desired force adjustment.
4
The setting is from 1-9, whereby 1 is the lowest value and 9 is the highest value.
The factory setting is 9.
1 - 9
Remote Control Programming
1
Press CODE, it displays “Su”.
2
Press a button on the remote control, then release and press the same
button again, “Su” flashes,
3
Then it displays “- - ” to show process is complete. Repeat this process to a
maximum of 20 different remotes and/or buttons.
37