39
2021-02-10 / V1.0
Contactors C195 Series – Installation and Maintenance Instructions
Maintenance
X
With the auxiliary switch actuator (6) held in place,
replace the cover (7) on the contact unit (2).
X
Make sure that the return spring (15) is in place
and correctly positioned.
7
6
15
2
Fig. 48: C195 X/: Place the cover with inserted connection
plate and contact bridge unit on the contact unit.
Disassembling/assembling the contact
bridge unit – type C195 X/
Requirements
-
The pole packs are disassembled, see section
“Disas-
sembling/assembling the pole packs – Typ C195 X/”
on page 35.
-
The pole plates are removed, see section
“Remov-
ing/inserting the pole plates – type C195 X/” on page
36.
-
The contact unit is disassembled, see section
“Disas-
sembling/assembling the contact unit – type C195
X/” on page 36.
-
The armature is disassembled, see section
“Disas-
sembling/assembling the armature – Typ C195 X/”
on page 37.
-
The cover is removed, see section
“Removing/at-
taching the cover – type C195 X/” on page 38.
-
The connecting plate is removed, see section
“Dis-
assembling/assembling the connecting plate –
type C195 X/” on page 38.
Disassembly
X
Remove the contact bridge unit (5) upwards from
the contact unit (2).
2
5
Fig. 49: C195 X/: Removing the contact bridge unit
Assembly
X
Insert the connecting plate (12) and contact bridge
unit (5) into the cover (7) and, with the auxiliary
switch actuator (6) held in place, place the cover
on the contact unit (2).
See section
„Disassembling/assembling the con-
necting plate – type C195 X/“ on page 38.