At the time of delivery, GreaseCheck is in its packaging and is preset
to the factory setting for the appropriate lubricant. The electronic
evaluation system and the sensor head are matched to each other.
There is no need to set GreaseCheck itself. It is only necessary to
find a position in which GreaseCheck can detect the current grease
condition.
Settings may only be made on GreaseCheck after consultation with
the manufacturer.
The basic settings are as follows:
■
grease:
– L
OAD
400
■
switch threshold:
– 90% of the relevant parameter.
A different configuration of GreaseCheck can be carried out by
the technical departments of Schaeffler Technologies AG & Co. KG.
A current list of greases that can be measured using GreaseCheck
can be found at
https://www.schaeffler.de/content.schaeffler.de/de/produkte-
und-loesungen/industrie/produktportfolio/instandhaltungs-
produkte/ schmierstoffueberwachung/index.jsp.
Operation
When the controller is connected to the power supply, the LED
will show red for approx. 5 seconds. In this bootloader mode,
external access is possible in order to change configurations.
The sensor then changes autonomously to measurement mode
(the status LED will show continuously green). As soon as data
communication is carried out via the bus, the status LED changes to
flashing green. The sensor generates new measurement values
at an interval of approx. 5 seconds, the current value is stored in
the memory and can be called up via the bus interface.
In order to ensure error-free measurement results, the grease grade
must not be changed during operation. During operation, no setting
work or checking is required.