Schaeffler Technologies
BA 35
15
Tighten the internal clamping screw using an open-end wrench
with an across flats distance of 13 mm and a tightening torque
of 4 Nm.
Pull the sensor head carefully in order to check that it is securely
seated.
Prevent any escape of grease at the mounting position by means
of appropriate measures.
The sensor head is fitted in the rolling bearing at the measurement
position.
Connecting the sensor head to
the electronic evaluation system
The sensor head should be attached to the electronic evaluation
system as follows:
Lay the connection cable of the sensor in such a way that it is
firmly laid and cannot flap. Observe the minimum bending radius
of the cable.
Connect the connection cable of the sensor to the appropriate
connection on the electronic evaluation system.
CAUTION
Hazardous radiation. Risk of damage to eyes due to radiation in
the infrared range. Do not look into the sensor optics while
the sensor head and electronic evaluation system are connected to
the power supply.
The sensor head and electronic evaluation system are connected.
���
Tapping of thread M8
���
Screwing in the internal
clamping screw
���
Inserting the sensor head
���
Tightening the internal
clamping screw to 4 Nm
Figure 5
Mounting of sensor head
00019C
02
00019C
02