STORAGE
COMPLETE TOOL EQUIPMENT
The pneumatic-hydraulic tool embedded in a shipping container must be stored in
environment with relative humidity to 70% and temperature ranging from +5°C to +40°C,
without aggressive evaporation of salts, acids and caustics.
3. GENERAL MAINTENANCE
General maintenance should be performed after about 500 000
strokes or once every three years. The whole tool must be completelly disassembled and all seals
and worn parts must be replaced. This repair may be carried out by an authorized technician only
or a person trained by the manufacturer or supplier.
Replaceable nose-pieces located in a plastic reservoir (Ø3.0/3.2, 4.0 and 4.8/5.0), jaws set,
Operations manual.
We recommend the customer to check completeness according the the above stated list (2.
LIST OF QUICKLY EXPENDABLE PARTS).
SPARE PARTS
1. ORDERING
Order the spare parts exlusively from the manufacturer or from your sales agents.
The order must contain:
a) tool serial number
b) number of ordered part
c) number of pieces
d) name of your company and precise address
e) your tax identification number and identification number
2. LIST OF QUICKLY EXPENDABLE PARTS
Assembly:
Mount the parts (see par. disassembly) in a reverse order. On the
outer surface of the jaws /fig.2 - pos.4/ apply a drop of lubricating
oil ( we recommend hydraulic oil grade HLP ISO VG 32), apply
thin layer of plastic lubricant MOGUL LV 2-3 to the suction
pipe and «O» ring /fig.2 - pos.7,6/. Basic set-up of the jaws is
performed as in fig. no. 3.
FIG.3
Designation
Reference
Nose-piece 2.4
D-06400124
Nose-piece 3.2
E-NEZ-RA-32
Nose-piece 4
E-NEZ-RA-40
Nose-piece 5
E-NEZ-RA-50
Clamping sleeve
D-1100103
Jaws
E-MORS-RA
Conduit suction complete
S-1100500
Front nozzle
D-1100600
Scraper ring
D-1100300
Nut HP
D-1100400
Mandrel container
S-1201402
Jaw pusher
E-POUSS-500-RA