#Bio25 11 – 140813
Page 17 of 40
7.4. Disassembly
1. Use Scanjet tool 25257 to remove
the round spring holding the
locking shafts in place, inside the
connection.
2. Remove the four locking shafts. This
can be done by rotating the entire
machine or by using a tool to force
them out.
3. When the locking shafts are out,
the inlet cone can easily be removed
by lifting it straight upwards.
4. Be sure to hold the
machine steady, use soft
material when holding it
to avoid damaging the
surface. Use Scanjet
tool 25255 to undo
the support bearing,
then insert the locking
shafts again. This is
done in order to line up
the stator and prevent
damages while undoing
the support bearing.
Note that the thread is a
right handed thread!