24
Dräger Interlock 7000
Use
The components are approved in accordance with the following
directives and standards:
The ABE (
Allgemeine Betriebserlaubnis—General Operating License
)
has the KBA code 91592.
3
Use
3.1
Installation
The installation may only be carried out by an authorized Dräger
Interlock service centre or a professional auto repair shop according to
the respective instructions for installation.
When choosing the installation site, the existing regulations for the
interior of vehicles have to be observed.
3.2
Requirements for a measurement
Do not allow a high alcohol concentration to reach the sensor, e. g.
from drinking alcohol, eating alcohol containing foods or rinsing
the mouth with alcoholic mouthwash just before measurement.
Component
Coding
Control unit
A
Camera
A
Handset
A, C
GPRS module
A, C
Coding
Directive/
Standard
Reference
A
(Interlock 5000/7000)
2014/30/EU
EMC Directive
2006/28/EC
EMC Directive,
motor vehicles
2009/19/EC
RFI suppression (EMC),
motor vehicles
EN 50436-1, -2
Alcohol Interlock, Europe
NHTSA / BAIID
Alcohol Interlock, USA
B
(Interlock 5000/7000)
2014/30/EU
EMC Directive
C
(Interlock 7000)
1999/5/EC
Radio, Europe
FCC Part 15
Radio, USA
IC RSS-210
Radio, Canada
NOTICE
Applied standards are listed with their date of issue in the
Declaration of Conformity.
i
i
WARNING
Alterations and additions to the device may cause danger.
Such alterations and additions invalidate the certificate of
installation contained in this instructions for use booklet.
WARNING
No alcohol and solvent vapours (disinfectants, window
cleaning fluids) in the ambient air.
Do not store in ambient air containing alcohol and solvent
vapours (disinfectants, window cleaning fluids).
!
!