Dräger Interlock 7000
33
Maintenance
6
Maintenance
6.1
Calibration / Adjustment
Only by an authorized Dräger Interlock service centre.
Check calibration at least every 12 months.
Once the service interval expires the display shows the message
Service due in X days
.
If the unit is not serviced, the vehicle can nevertheless be
started during a transition period of several days (dependent on
the configured parameters).
6.2
Cleaning
To clean, wipe with a disposable tissue.
Do not submerge in liquid – liquid must not enter the sockets!
7
Disposal
Dispose of the product in accordance with the applicable rules and
regulations.
7.1
WEEE
8
Technical data
This product must not be disposed of as municipal waste.
This is indicated by the adjacent icon.
You can return this product to Dräger free of charge. For
information please contact the national sales organisations
and Dräger.
Measuring principle
Electrochemical DrägerSensor
Measuring range
Up to 3.0 mg/L
Ambient conditions
For operation and storage -40 °C to 85 °C
20 % to 98 % r. h.
600 to 1100 hPa
No influence of changes in altitude
on the measurement result
Sensitivity drift
Typically 1 % of measured value /
month
Display
Display
Calibration interval
Typically 12 months
Dimensions (H x W x D)
Handset
Approx. 138 mm x 61 mm x 36 mm
Control unit
Approx. 148 mm x 90 mm x 32 mm
Weight
Interlock 5000 handset
Approx. 180 g
Interlock 7000 handset
Approx. 178 g
Control unit
Interlock 5000
Approx. 195 g
Control unit
Interlock 7000
Approx. 240 g
Voltage supply
12 V to 24 V