19:03-15
ã
Scania CV AB 2002, Sweden
11
Routing the FAS wiring
1
Open the central electric unit.
2
Lay the FAS wiring behind the central
electric unit.
3
Set the outlet air control 2 in the middle
position and remove it from the instrument
panel. The controls must be set to minimum
position to remove the outlet.
4
Detach the panels D, E and F.
5
Press the hand-held computer cradle into
panel D and screw on the attaching plate.
Note:
The hand-held computer cradle should be
located in panel D. If there is a diagnostic switch
panel located in panel D, it can be moved to
panel F.
6
Fit the spring-loaded switch for the telephone
into a spare hole in panel D, E or F.
7
Place the telephone symbol label in the hole
in the panel associated with the button.
8
Run the FAS wiring between the central
electric unit and panel D and connect to the
central electric unit.
9
Connect the wiring to the hand-held
computer cradle and the switch.
Note:
Connector C461 is an additional CAN
socket and is not connected.
12
55
15
D
E
F 2