3.7.
Dosing Target values
•
Target adjustment screen can be displayed
•
According to the Feed sequence setting, the following screen are displayed:
Parameter
Possible Value
Target values Adjustment
CF only
FF-CF-
FF-(CF+FF)
Target weight
0 – 1 000 000
CF to FF Level
0 – 1 000 000
FF to CF Level
HF to CF Level
20
User manual SCAIME:
NU-eNodTouch-E-0413
displayed from the Setup menu or directly from the main screen with
setting, the following screen are displayed:
Description
CF only CF-FF
(CF+FF)-FF
-FF HF-CF-FF
+FF)-FF (HF+CF+FF)-(CF+FF)-FF
(HF+CF)-CF-FF
Target weight represents the value to reach at the end of the dosing
process.
Used in sequences using at least 2 or 3 feeds.
Defines the transition threshold, relative to the target weight
Coarse feed and Fine Feed phase.
Used in sequences where FF comes before a CF phase.
Defines the transition threshold, relative to the target weight
Fine Feed and Coarse Feed phase.
Used in sequences using 3 feeds.
Defines the transition threshold, relative to the target weight
High Feed and Coarse Feed phase.
Setup menu or directly from the main screen with
touch.
FF
to reach at the end of the dosing
relative to the target weight, between the
Used in sequences where FF comes before a CF phase.
relative to the target weight, between the
relative to the target weight, between the