36
User manual SCAIME:
NU-eNodTouchM-E-0815_196774-B
Ethernet Parameters
IP
IP address
Mask
Subnet mask
Gateway
Default gateway (must match with IP address and Mask)
DHCP
Assignment of IP address from a DHCP server on this subnet
Swap data
Swap data (bytes) in Modbus TCP registers (16 bits words)
Name
Profinet station name (up to 10 char with Option « Use rotary switch in Name » else 15,
lower case, figures, dots and dashes only)
Option « Use rotary
switch in Name »
Allows on Save automatic appending of hexadecimal representation of rotary switches in
the Name.
Byte order
Byte order in Profinet exchanges ([Little Endian], [Big Endian])
Содержание eNodTouch-M
Страница 5: ...5 User manual SCAIME NU eNodTouchM E 0815_196774 B 1 2 Dimensions 1 2 1 eNodTouch M ...
Страница 6: ...6 User manual SCAIME NU eNodTouchM E 0815_196774 B 1 2 2 eNodTouch ML ...
Страница 32: ...32 User manual SCAIME NU eNodTouchM E 0815_196774 B 3 5 4 I O Setup eNod4 T eNod4 D eNod4 C ...