33
User manual SCAIME:
NU-eNodTouchM-E-0815_196774-B
Parameter Possible
Value
Description
Input 1-2 Parameters
Function
Function assigned to the related input : None, Zero, Tare, Clear, Start cycle, stop cycle, Suspend
cycle, Dynamic Zero, Manual emptying
Logic
[Positive]-[Negative]
defines the edge (or level) that triggers input function
Debounced time
0 - 65535
Minimum required time of the logical inputs before their activation
Output 1-4 Parameters
Function
Function assigned to the related output : None, Thresholds, Stability, Coarse feed, High feed, fine
feed, Cycle ongoing, result available, Out of tolerance, Dosing fault, Input copy, Remote control,
Out of tol, Out of tolerance –
Logic
[Positive], [Negative]
Defines idle output state.
Mode
[Windows], [Hysteresis]
Thresholds functioning principle
Comparison
[Gross], [Net], [result]
Comparison value for thresholds control