Feeds sequence
eNod4-D could manage up to 3 feeds: High Feed (HF), Coarse Feed (CF), Fine Feed (FF). The
number and order of used feeds during a cycle is configured by this parameter.
Auto. TARE at Start
[Yes], [No]
If enable, TARE function is operated after each dosing cycle start
Page 2/3
Emptying / reloading
[No], [At End],
[At Start]
define the activation / deactivation and position of emptying (Reloading in
unloading mode) option
Emptying mode
[Auto], [Manual]
In filling mode, define the emptying mode: In manual mode, emptying
start after input ‘Manual Emptying’ activation
Emptying end level
0 – 1 000 000
The ‘emptying’ output is disabled if the net value becomes inferior to this
level and if the ‘emptying holding time’ has elapsed.
Reloading Min Level
0 – 1 000 000
Output assigned to the reloading function is activated if the gross
measurement is less than reloading Min Level, until the measurement
become greater than reloading max Level.
Reloading Max Level
0 – 1 000 000
Page 3/3
Dynamic mode
[Yes], [No]
Selecting this option replaces the stability condition for taking tare /
results by averaging measurements over the ‘Calc time Tare/Result’.
Activ FF if OUT-
[Yes], [No]
In filling mode, this option automatically restart the Fine Feed if dosing
result is below low tolerance
Suspend/Resume
cycle allowed
[Yes], [No]
Allows SUSPEND and RESUME cycle. It makes possible to restart a dosing
cycle when starting weight is greater than "empty max. weight".