ENGLISH
9
3.2 Power Controller
The Power controller must not be located
inside the sauna room or in places
where temperature can exceed 40°C.
It is protected against water splashes,
however it should not get in contact with
water. Mount the Power Controller in a dry
location, outside the sauna room.
Install the Power Controller on the wall in
vertical direction only, at least 30cm from
the ceiling (refer to Fig.2).
The heater is connected to the electrical
network semi-stationarily with a H07RN-F
rubber cable or its equivalent. The use of
PVC-insulated cable as a connecting cable
is prohibited due to thermal embrittlement.
The maximum distance of the junction box
from the floor is 500 mm, measured from
the upper corner of the box.
WARNING
Do not embed the control unit into the wall,
because it may lead to overheating of the unit
and cause damage!
3.3 Contactor Unit
If the heater used is more than 9 kW,
an additional contactor is needed. The
contactor unit is linked to the main Power
Controller with RJ cable (Fig.4).
Follow the instructions that are supplied
together with the contactor unit.
Fig. 2
Fig. 4
Fig. 3
CEILING LEVEL
300 mm
MIN.
*Install the Power
Controller in vertical
direction only.
POWER CONTROLLER
CONTACTOR UNIT
SEPARATE CONTROL
USER INTERFACE
RJ Cable
RJ Cable