ENGLISH
13
Sensor 2 (Optional)
Temperature Sensor
Air Vent
See Airvent
installation
min 200mm from
the wall
CEILING
FLOOR
WALL
WALL
WALL
Sensor
Sensor
Air Vent
Air Vent
See Airvent Installation
See Airvent Installation
SENSOR LOCATION
Top view
Side view
Sauna Type
Domestic sauna
Hotels, Condominiums
Public sauna
DIP switch
1,2,3
1h
Sauna on-time
Heater on-time
Session time
2h
4h
001
010
011
000
100
101
110
111
6h
8h
12h
18h
24h
5h 15min-
sauna
5h 45min-
sauna
Max. time
Max. pre-run time
99h
EMPTY
SAFETY
SLAVE
COMBI
SESSION
1
=
=
ON
OFF
0
Fig. 8
Fig. 10
Fig. 11
Fig. 9
3.5.2 Sensor location with heaters mounted on
the floor more than 200mm from the wall
3.6 Maximum Session Time
The maximum sauna session time depends
on the purpose of the sauna. For domestic
use, the total on-time of the sauna is limited
to 6 hours. *)It includes pre-run time and
the session time. The factory setting for the
control unit is 6 hours.
For condominiums, hotels and similar
locations, the operating period of the sauna
heater is limited to 12 hours, including the
pre-run time and the session time.
For public sauna, the operating period of
the sauna heater can be either 18 or 24
hours. Please note, if the switches is set to
24 hours, it will be ON constantly. It needs to
be continuously monitored.
The maximum heater on-time is set by the
switches on DIP switch in the power controller,
Figure 11 (See also DIP switch session time
settings (4.2) in page 16. Only a qualified
electrician can change the settings. The
standards and regulations of the country
where the control unit is installed must be
followed when setting the DIP switch. Default
time is 6 hours. See the Figure 10.
*) IEC 60335-2-53