ENGLISH
16
Session
Time
Switch
2
Switch
1
Switch
3
1
=
=
ON
OFF
0
DIP Switch #
Function
ON
OFF
1
1h
2h
4h
6h
8h
12h
18h
24h
0
0
0
0
1
1
1
1
0
1
1
0
0
0
1
1
1
0
1
0
0
1
0
1
Session time
Session time
Session time
Combi mode
Slave
-
-
-
Empty
Safety/door switch
*Safety switch
Combi mode OFF
Controller
**Door switch
Contactor
Combi heater with
1 signal (Wm) for
water level detection
Combi heater with
2 signal (Empty & Level)
for water level detection
Combi mode ON
2
3
4
5
6
7
8
EMPTY
SAFETY
SLAVE
COMBI
SESSION
4. DIP SWITCH
4.1 DIP Switch Functions
In DIP switch #8, the Safety Switch function is available when it is switched ON and Door Switch function when
it is OFF. Both functions cannot work at the same time.
4.1.1 *Safety Switch
The safety switch function is for a triggering device that will cut the heater connection when a combustible
foreign object is thrown to the heater.
4.1.2 **Door Switch
Install a door sensor and connect it to the control. A signal is channel to the control when the door is open.
The control will switch OFF when the door is open during PRE-RUN. When the control is in ON MODE and the
door was left open for more than 15mins, the control will switch OFF and turn ON again when the door is close.
4.2 Session Time
Session time can be set according to user preference by session dip switches on the power controller board.