21
9
English
The power controller or the separate
control panel must not be located inside the
sauna room or in places where temperature
can 40°C. It is protected against
water splashes, however it should not get in
contact with water. Mount the controller
board on a dry location, outside the sauna
room.
Install the Power Controller Board on the
wall in vertical direction only and at least
30cm from the ceiling (refer to Fig.3).
4.2 Power Controller
If the heater used is more than 15kW, an
additional contactor is needed. The contac-
tor unit is linked to the main Power Control-
ler Board with a RJ12 cable (Fig.5).
4.3 Contactor Unit
Stainless Steel Touch Control
Touch Control
Installation of separate Control
Panel and Power Controller with
Contactor Unit
POWER CONTROLLER
CONTACTOR UNIT
RJ12 Cable
SEPARATE CONTROL
PANEL
The heater is connected to the electrical
network semi-stationarily with a H07RN-F
rubber cable or its equivalent. The use of
PVC-insulated cable as a connecting cable
is prohibited due to thermal embrittlement.
The maximum distance of the junction box
from the floor is 400 mm, measured from
the upper corner of the box.
Fig.5
Follow the instructions that are supplied
together with the contractor unit.
CEILING LEVEL
300 mm
M
IN.
*Install the Power
Controller in vertical
direction only.
Fig.3
Fig.4
WARNING
Do not embed the control unit into the wall,
because it may lead to overheating of the
unit and cause damage!
POWER CONTROLLER
CONTACTOR UNIT
SEPARATE CONTROL
PANEL
RJ12 Cable
RJ12 Cable
RJ12 Cable