17
2.7.2 Humidity & Temperature in the Sauna
2.7.3 Cabin Drying
2.7.1 Steamer
2.7 Combi Features
These features for steamer are only appli-
cable with Combi heaters.
If during the steamer session the operation
mode is changed to heater only, there will
be no drying time at the end of the session.
You can abort cabin drying by pressing the
ESC button.
High humidity and high temperature are not
allowed simultaneously in the sauna room.
When sauna session is switched to steamer
session, sensors will check that the
temperature or the relative humidity inside
the sauna room is not too high.
If the temperature or relative humidity is
too high, the steamer will not be activated.
Steamer activation depends on the second
sensor, the bench sensor. If it is a tempera-
ture sensor only, and the bench tempera-
ture in the sauna room is 56°C or more, the
steamer cannot be activated. The user can
choose the relative time for the steamer to
be on, within 30-100% of the session time.
However, if the second sensor is combined
temperature / humidity sensor, the
maximum bench temperature for the
steamer to activate is 80°C, as long as the
relative humidity in the sauna room is not
too high. With the combined sensor, the
user can choose the relative humidity inside
the sauna room.
The standard drying time is set for 30
minutes at 70°C. If the fan is connected
with the control unit, it will be running at
100%, during the cabin drying. The cabin
drying is set to begin 10 minutes after the
steamer session. Therefore, the actual
drying time is 20 minutes.
English