8 TROUBLESHOOTING
8. TROUBLESHOOTING
The safety information from section 2 “safety” must be observed.
DANGER!
Hazard from malfunction!
Incorrect assembly of the demagnetiser can cause a malfunction of the
machine.
This can cause crushing and jamming points, posing a risk of crushing for
limbs.
■
Have troubleshooting carried out only by qualified personnel.
■
Re-install safety devices correctly.
DANGER!
Risk of crushing!
There is a risk of limbs being crushed by the demagnetiser falling due to
incorrect installation and removal of the magnets.
■
Secure the demagnetiser against falling.
■
Have troubleshooting carried out only by qualified personnel.
DANGER!
Risk of electric shock!
The alternating magnetic field is generated with alternating voltage.
Demagnetisers work with high voltages and currents. An electric shock can
result in death or serious injuries.
■
Before troubleshooting, always disconnect the demagnetiser from the
power supply.
■
Ensure to protect the device, rubber cable and connector against damage.
■
To exclude malfunctions and hazards for the operator, it is not permitted
to open the hand-held demagnetiser.
Demagnetiser does not switch on
■
The demagnetiser is not connected to the power supply. Check the connection.
■
Demagnetiser defective. Send the demagnetiser to SAV GmbH for repair.
Demagnetiser has no effect
■
Distance between workpiece and demagnetiser too large. Reduce the distance.
■
Workpiece diameter too large. Demagnetise the workpiece from several sides.
Contact SAV Service if necessary.