Instruction Manual 

FH 

PEAK: 

Three functions available: 
-

Track mode (continuous measurement) 

-

Peak mode (capture of maximum values) 

-

Auto-Peak  mode,  same  as  Peak-mode,  only 
without the „Min limit peak save“ function 

MEMORY: 

Saves  the  peak  values  to calculate  the  average 
value (please see section 

“Memory mode” 

DELETE Function 

Deletes  stored  peak  values  (only  in 

„Memory 

mode

“  active) 

PRINT: 

Sends the stored peak values to a PC or Printer 
(plea

se see section „Data Output”) 

High / Low limit function 

LEDs to display OK / NOT OK Tests 

▼ 

Lower than lower limit 

● 

Lights if the STOP value is reached 

▲ 

Higher than highest limit 

This  function  allows  efficient 

testing  of  OK  /  NOT  OK’S 

measurements of similar or identical testing objects. 
A  lower  and  an  upper  limit  value  can  be  defined.  The 
instrument compares the individual measuring results with 
these limit values and shows the OK or NOT OK result by 
green or red light diode and by sound. 
To  set  these  limit  values,  please  see  the  SET  Menu  in 
section „Operating keys“. 

Measurement (Track Modus) 

Display  (1)  shows  the  continuous  force  in  a  defined 
direction (6) 

To zero the display, press: 

Peak-Hold Function (Peak Mode) 

Please press: 

Auto-Peak-Hold-Function (Auto-Peak Mode) 

Please press: 

Min.  limit  peak  function  to  activate  storage  of 
measurements 

This 

function  allows  to  eliminate  unwanted  „Pre-Peak 

values“ that are lower than the main peak value (Fp). The 
“Min  limit  peak  save”  value  (Fo)  takes  care,  that  these 
“Pre-Peak values” are not saved. 
The „Min limit peak save“ function is only possible in Peak-
Mode. 
To  set  this  Min  limit  value,  please  see  the  SET  Menu  in 
section „Operating keys“. 

Memory  mode  and  average  value 

(from  up  to  10  peak 

values) 

Saving peak values in the instrument 

Activating the „AUTO PEAK Function“ by PEAK key 

Deactivating the „Average Function“ by MEMORY key 

Now, all peak values are stored automatically in the 

instrument 

To browse through the stored values, please use the ▲ 

or ▼ keys. (The values will be shown in the upper 
display segment) 

By pressing the MEMORY key, the average value of the 

stored peak values can be shown (in the upper display 
segment) 

To delete every stored value, press the▼-key in the 

AVERAGE-Mode 

FH_SI-BA-e-1317 

Содержание FH-S

Страница 1: ...cl rechargeable battery Carrying Case Charger Standard Attachments as shown below 5 pcs M3 x 8 screws Power plug Reset button Display Pilot lamp RS 232 port Force Sensor Sensor Inside Important annotation By pressing the RESET key on the right side of housing see illustration on the left individual settings and memorised values can be re set or erased in example for a new start of the instrument a...

Страница 2: ...ent off after a here defined time 9 AVERAGE or Saving Mode period in sec P OFF To change press or Only active in Battery Mode Operation keys ON OFF 1 x Press Peak Freeze Time PE 2E ON OFF key A PE HoldT Time period in sec in For ON press 1 sec which a peak value is being shown in the display in sec To change press or UNIT 1 x Press Data Transfer rS232 to PC Press shortly Select unit P OFF HoldT St...

Страница 3: ...ound To set these limit values please see the SET Menu in section Operating keys Measurement Track Modus Display 1 shows the continuous force in a defined direction 6 To zero the display press Peak Hold Function Peak Mode Please press Auto Peak Hold Function Auto Peak Mode Please press Min limit peak function to activate storage of measurements This function allows to eliminate unwanted Pre Peak v...

Страница 4: ...material to be measured incorrect measuring results can be displayed due to the stability compensation in the instrument Example Slow draining off of liquid from a container suspended from the instrument Do not attach a continuous load This can damage the measuring unit as well as the parts relevant to safety Prevent jolts torsion and oscillation e g by appending slopingly of all kinds Be sure to ...

Страница 5: ...in KERN s accredited DKD calibration laboratory return to national normal Fundamental safety information Do not use the hanging instrument to transport loads Prevent jolts torsion and oscillation e g by appending slopingly of all kinds Never use the hanging instrument over the maximum permitted weight Danger of breaking Always make sure that there are no living beings or materials below the load t...

Страница 6: ...he instrument has to be shut off Start again with 1 Eventually pressing the buttons faster 4 Select the Press instrument type 5 Save Press SET instrument type 6 Enter the Press MEMORY adjustment sequence 7 Choose the Press UNIT and adjustment with specify the weight calibration weight in Newton X kg 9 81 8 Save the Press SET and UNIT adjustment simultaneously weight 9 Attach the Press ZERO weight ...

Отзывы: