Instruction Manual

 

FH

 

SET: 

4. 

Technical Data 

-

1  x  Press:  Upper  Limit  [HidT  /  Hi  Lt].  To 

-

Accuracy:  ± 0,5 % of Capacity (measuring range) 

change  press:  ▲  or  ▼  (see  section 

-

Data Sampling Rate:  2.000 Hz 

High/Low Limit function) 

-

Weight:  640 g 

Hi Lt 

-

1  x  Press:  Lower  Limit  [LodT].  To  change 

5. Operation 

press ▲ or ▼ (see section High/Low Limit 
function) 

Display 

-

1 x Press: Sets the Auto-STOP force value 
that  stops  the  movement  of  a  test  stand. 

(1)  Measuring Result 

Adjustment  of  the  force  value.  To  change 

(2)  Measuring Units 

press:  ▲  or  ▼  (only  active  in  „Battery­

(3)  Activation of PRINT Function 

Mode“) 

(4)  Indication of power charging status 
(5)  PEAK or AUTO-PEAK Mode 
(6)  Average value of stored peak values 
(7)  Force direction 

1  x  Press:  Auto-OFF  Function.  Turns  the 

(8)  Occupancy of storing spaces 

instrument  off  after  a  here  defined  time 

(9)  AVERAGE- or Saving Mode 

period in sec. 

[P.OFF]. To change press: ▲ 

or ▼ (Only active in „Battery-Mode“) 

Operation keys 

ON / OFF: 

-

1  x  Press:  Peak-Freeze-Time  [PE.2E  / 

ON / OFF key 

A.PE  /  HoldT]:  Time  period  (in  sec.)  in 

(For ON, press 1 sec.) 

which  a  peak  value  is  being  shown  in  the 
display in sec. 

To change press: ▲ or ▼ 

UNIT: 

-

1  x  Press:  Data  Transfer  [rS232]  to  PC 

-

Press shortly: 

Select unit: 

P.OFF 

HoldT 

StoP 

(PC) or to the printer (Print) or (in version U 

N, kg or lb 

5.1) to the test stand

 

-

Press for 2 sec.: 

Display return

 

rS232 

ZERO: 

Lo dT 

Lo Pe 

-

1  x  Press:  Minimum  limit  to  save  peak 
values  in  the  instrument’s  memory. 
[LE.SET  /  Lo  Pe]. 

Please see section „Min 

Limit  Peak  Save“.  To  change  press:  ▲  or 
▼  (Only  active  in  „Peak-Mode“)  (see 
section min. limit peak save) 

- PC: Pressing SET once: Saves the Settings 

Three functions: 

- PRINT: Pressing SET twice: sending data to the printer 

-

Zeros the measuring result (Tara function) 

-

Cleans the peak value (in Peak mode) 

- STAND: Pressing SET three times: sending a signal to 

-

Saves a setting (in SET mode) 

the Test Stand to stop its movement (in version U 5.1) 

BACK LIGHT: 

FH_SI-BA-e-1317 

Содержание FH-S

Страница 1: ...cl rechargeable battery Carrying Case Charger Standard Attachments as shown below 5 pcs M3 x 8 screws Power plug Reset button Display Pilot lamp RS 232 port Force Sensor Sensor Inside Important annotation By pressing the RESET key on the right side of housing see illustration on the left individual settings and memorised values can be re set or erased in example for a new start of the instrument a...

Страница 2: ...ent off after a here defined time 9 AVERAGE or Saving Mode period in sec P OFF To change press or Only active in Battery Mode Operation keys ON OFF 1 x Press Peak Freeze Time PE 2E ON OFF key A PE HoldT Time period in sec in For ON press 1 sec which a peak value is being shown in the display in sec To change press or UNIT 1 x Press Data Transfer rS232 to PC Press shortly Select unit P OFF HoldT St...

Страница 3: ...ound To set these limit values please see the SET Menu in section Operating keys Measurement Track Modus Display 1 shows the continuous force in a defined direction 6 To zero the display press Peak Hold Function Peak Mode Please press Auto Peak Hold Function Auto Peak Mode Please press Min limit peak function to activate storage of measurements This function allows to eliminate unwanted Pre Peak v...

Страница 4: ...material to be measured incorrect measuring results can be displayed due to the stability compensation in the instrument Example Slow draining off of liquid from a container suspended from the instrument Do not attach a continuous load This can damage the measuring unit as well as the parts relevant to safety Prevent jolts torsion and oscillation e g by appending slopingly of all kinds Be sure to ...

Страница 5: ...in KERN s accredited DKD calibration laboratory return to national normal Fundamental safety information Do not use the hanging instrument to transport loads Prevent jolts torsion and oscillation e g by appending slopingly of all kinds Never use the hanging instrument over the maximum permitted weight Danger of breaking Always make sure that there are no living beings or materials below the load t...

Страница 6: ...he instrument has to be shut off Start again with 1 Eventually pressing the buttons faster 4 Select the Press instrument type 5 Save Press SET instrument type 6 Enter the Press MEMORY adjustment sequence 7 Choose the Press UNIT and adjustment with specify the weight calibration weight in Newton X kg 9 81 8 Save the Press SET and UNIT adjustment simultaneously weight 9 Attach the Press ZERO weight ...

Отзывы: