Instruction Manual

 

FH

 

6. Configuration of RS 232 

SUB-D 9pm 

Pin 

Signal 

Illustration 

TxD 

Output signal 

RxD 

Input signal 

GND 

Ground 

+1.6 to + 2 V 

Over upper limit 

+1.6 to + 2 V 

Lower than lower limit 

+1.6 to + 2 V 

OK 

6.1 Output Protocol 

RS-232 Parameter 
Baud rate: 

9600 

Data-Bit: 

Parity: 

none 

Stop-Bit: 

The measured value is requested by the PC by the ASCII 
Sign “9”. 

The measured value that comes from the instrument has 
this format: 

e.g. 

0011.70 

means  -11,70 Newton, if 

Newton is the selected unit 

||-----| 

|____> 

the other 6 places describe the 

measured value as ASCII-Signs 

|_______> 

the first place describes the 

direction of the force (0 = minus = Pressure; 

1 = plus = Tension) 

or:  1021.15  means  +21,15 N  (Tension) 

|_______>  the first place describes the 

direction of the force (0 = minus = Pressure; 

1 = plus = Tension) 

or:  1021.15  means  +21,15 N  (Tension) 

7. Warning 

Intended use 

The instrument you have acquired serves to determine the 
measuring value of the material to be measured. It is 
intended to be used as a “non-automatic“  instrument, i.e. 
the material to be measured is manually and carefully 
attached at the instrument. The measuring value can be 

read off after a stable measurement value has been 
obtained. 

Inappropriate use 

Do not use the instrument for medical measurements. In 
the event that small quantities are removed or added to the 
material to be measured, incorrect measuring results can 
be displayed due to the “stability compensation“ in the 
instrument. (Example: Slow draining off of liquid from a 
container suspended from the instrument). Do not attach a 
continuous load. This can damage the measuring unit as 
well as the parts, relevant to safety. 

Prevent jolts, torsion and oscillation (e.g. by appending 
slopingly) of all kinds. Be sure to prevent overloading the 
instrument in excess of the stated maximum load (max.), 
minus any tare weight that may possibly exist. This could 
damage the instrument (risk of breakage). 

Important: 

• Always make sure that there are no people or materials 
below the load that could be injured or damaged! 
• The instrument is not suitable for measuring people. Do 
not use as baby scales! 
• The instrument does not comply with the medical product 
law (MPG). 
Never operate the instrument in hazardous locations. The 
series design is not explosion-proof. Structural alterations 
may not be made to the instrument. This can lead to 
incorrect measuring results, faults concerning safety 
regulations as well as to destruction of the instrument. The 
instrument may only be used in compliance with the 
described guidelines. Varying areas of application/ planned 
use must be approved by SAUTER in writing. 

Guarantee 

The guarantee is not valid in following cases: 

• Non-observation of our guidelines in the operating 
instructions 

• Use outside the described applications 

• Alteration to or opening of the device 

• Mechanical damage and damage caused by media, 

liquids 

• Natural wear and tear 

• Inappropriate erection or electric installation 

• Overloading of the measuring equipment 

FH_SI-BA-e-1317 

Содержание FH-S

Страница 1: ...cl rechargeable battery Carrying Case Charger Standard Attachments as shown below 5 pcs M3 x 8 screws Power plug Reset button Display Pilot lamp RS 232 port Force Sensor Sensor Inside Important annotation By pressing the RESET key on the right side of housing see illustration on the left individual settings and memorised values can be re set or erased in example for a new start of the instrument a...

Страница 2: ...ent off after a here defined time 9 AVERAGE or Saving Mode period in sec P OFF To change press or Only active in Battery Mode Operation keys ON OFF 1 x Press Peak Freeze Time PE 2E ON OFF key A PE HoldT Time period in sec in For ON press 1 sec which a peak value is being shown in the display in sec To change press or UNIT 1 x Press Data Transfer rS232 to PC Press shortly Select unit P OFF HoldT St...

Страница 3: ...ound To set these limit values please see the SET Menu in section Operating keys Measurement Track Modus Display 1 shows the continuous force in a defined direction 6 To zero the display press Peak Hold Function Peak Mode Please press Auto Peak Hold Function Auto Peak Mode Please press Min limit peak function to activate storage of measurements This function allows to eliminate unwanted Pre Peak v...

Страница 4: ...material to be measured incorrect measuring results can be displayed due to the stability compensation in the instrument Example Slow draining off of liquid from a container suspended from the instrument Do not attach a continuous load This can damage the measuring unit as well as the parts relevant to safety Prevent jolts torsion and oscillation e g by appending slopingly of all kinds Be sure to ...

Страница 5: ...in KERN s accredited DKD calibration laboratory return to national normal Fundamental safety information Do not use the hanging instrument to transport loads Prevent jolts torsion and oscillation e g by appending slopingly of all kinds Never use the hanging instrument over the maximum permitted weight Danger of breaking Always make sure that there are no living beings or materials below the load t...

Страница 6: ...he instrument has to be shut off Start again with 1 Eventually pressing the buttons faster 4 Select the Press instrument type 5 Save Press SET instrument type 6 Enter the Press MEMORY adjustment sequence 7 Choose the Press UNIT and adjustment with specify the weight calibration weight in Newton X kg 9 81 8 Save the Press SET and UNIT adjustment simultaneously weight 9 Attach the Press ZERO weight ...

Отзывы: