11
ENG
4
- INSTA
LL
ATION OF THE
U
NIT
4
.5- INSTA
LL
ATION OF THE DECORATIVE PANE
L
1
A badly mounted cover can lead to unwanted
condensed water leakage on the inside of the
cassette and cause anomalies in the display.
2
Ensure that the unit is installed in the correct
position. To attain this, the unit should be
mounted horizontally and level with the lower
edge of the fi nished ceiling.
3
Verify the size of the opening in the ceiling.
After the cover has been mounted, the opening
in the ceiling should be hidden.
4
When setting the decorative panel into place,
ensure not to place the air swing motor under
the refrigerant pipes.
5
Firstly, provisionally secure the screws on the
cover in order to proceed to level it.
6
After levelling the cover, tighten the screws
securely.
7
Connect the synchronous motor cables and the
signal lines.
8
Perform a trial run.
9
If there is no response to the remote control
signal, check the connection. Repeat the trial
run 10 seconds later after disconnecting and
reconnecting the power supply.
4
.
6
- PIPE CONNECTION
1
Upon connecting the water pipes, ensure that
it is possible to access the switches on the
devices in the inner unit.
2
Remove the insulation of the fl ared connection
in the unit.
3
Cut the pipes, leaving enough extra piping
hanging over to enable the unit to be joined up
to the outdoor unit joins.
4
Carefully bend the connection pipes in the
unit in the desired direction (Warning: Do not
completely fl atten the pipe!).
5
Do not forget to insert the nut before drilling.
6
Drill the water pipe when installed.
7
Connect the water pipes and the condensed
water hose to the corresponding pipe and
installation drain.
8
Insulate the water piping correctly. To do so,
cover any possible cuts with masking tape or
insulate any bare refrigerant piping with the
corresponding insulation material used for
cooling.
9
Ensure that each of the installation pipes is
properly insulated and separated.
Содержание 2-035 AK
Страница 21: ...21 ESP NOTAS...
Страница 22: ...ESP 22 NOTAS...
Страница 23: ...23 ESP NOTAS...
Страница 25: ...ITA UNIT A CASSETTA Manuale d installazione UNIT A CASSETTA 2 035 AK 2 050 AK 2 075 AK 2009...
Страница 45: ...21 ITA NOTE...
Страница 46: ...ITA 22 NOTE...
Страница 47: ...23 ITA NOTE...
Страница 49: ...FRA CASSETTE Manuel d installation CASSETTE 2 035 AK 2 050 AK 2 075 AK 2009...
Страница 69: ...21 FRA REMARQUES...
Страница 70: ...FRA 22 REMARQUES...
Страница 71: ...23 FRA REMARQUES...
Страница 73: ...ENG CASSETTE Installation Manual CASSETTE 2 035 AK 2 050 AK 2 075 AK 2009...
Страница 93: ...21 ENG NOTES...
Страница 94: ...ENG 22 NOTES...
Страница 95: ...23 ENG NOTES...
Страница 97: ...POR CASSETE Manual de Instala o CASSETE 2 035 AK 2 050 AK 2 075 AK 2009...
Страница 117: ...21 POR NOTAS...
Страница 118: ...POR 22 NOTAS...
Страница 119: ...23 POR NOTAS...
Страница 121: ...HRV KAZETA Upute za instalaciju KAZETA 2 035 AK 2 050 AK 2 075 AK 2009...
Страница 141: ...21 HRV NAPOMENE...
Страница 142: ...HRV 22 NAPOMENE...
Страница 143: ...23 HRV NAPOMENE...