background image

SATEL INT-KWRL 

 

 

Fig. 4. DLOADX

 

program: keypad settings stored in the ABAX system controller. 

 

4.2  Settings stored in the control panel 

These settings you can configure: 

 DLOADX program: 

“Structure” window 

“Hardware” tab 

“Expansion modules” branch 

[keypad name] 

(see Fig. 5), 

 LCD keypad: 

S

ERVICE MODE

 

S

TRUCTURE

 

H

ARDWARE

 

LCD

 KEYPADS

 

S

ETTINGS

 

[keypad name]

4.2.1  Description of parameters and options 

Given in the square brackets are the names of parameters and options presented on the 
keypad display. 

Keypad 

Name

 – individual name of the keypad (up to 16 characters). 

Partitions managed by keypad

 [Partitions] – partitions which can be armed/disarmed or 

alarm in which may be cancelled from the keypad. These functions are available to the 
users having appropriate rights and access to these partitions. 

Using the service code you can operate all partitions, irrespective of which partitions 
are operated by the keypad. 

Содержание INT-KWRL

Страница 1: ...int kwrl_en 05 18 Wireless keypad INT KWRL Firmware version 2 15 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 www satel eu...

Страница 2: ...nually upgrade the quality of its products which may result in some changes of their technical specifications and firmware The current information on the introduced modifications is available on our w...

Страница 3: ...5 03 or newer connected to the INTEGRA INTEGRA Plus control panel The ACU 120 ACU 270 controller which is to support the INT KWRL keypad must be connected to the expander bus controller terminals CKE...

Страница 4: ...e mode is entered after 20 seconds since the last key press after preset time if the active mode was started automatically see description of the WAKE UP parameter section Settings stored in ABAX syst...

Страница 5: ...ect installation of the battery The used batteries must not be discarded but should be disposed of in accordance with the existing rules for environment protection The keypad is designed for indoor in...

Страница 6: ...of the mounting holes 8 Drill the holes in the wall for wall plugs screw anchors 9 Using wall plugs screw anchors and screws secure the enclosure base to the wall Select wall plugs and screws specifi...

Страница 7: ...cel adding the keypad click on the Quit button 9 The New device window will close 10 The new keypad will appear in the table in INT KWRL tab 11 Click on the Keypads identification button the new keypa...

Страница 8: ...roller name INT KWRL tab see Fig 4 LCD keypad SERVICE MODE STRUCTURE HARDWARE EXPANDERS SETTINGS controller name SETTINGS wireless keypad name 4 1 1 Description of parameters and options Given in the...

Страница 9: ...cription of parameters and options Given in the square brackets are the names of parameters and options presented on the keypad display Keypad Name individual name of the keypad up to 16 characters Pa...

Страница 10: ...keypad can inform on fire alarms in selected partitions CHIME signal of zones Chime zones zones the violation of which is audibly signaled by the keypad If the zone is armed violation will not trigger...

Страница 11: ...ime format the way how date and time will be presented on the display LCD backlight the way how the display backlight will work in the active mode not present disabled permanent 50 enabled brightness...

Страница 12: ...ne of the display Exit delay clearing enable Fin exit delay if this option is enabled the exit delay time in partitions with the EXIT DELAY CLEARING option enabled can be shortened after pressing in t...

Страница 13: ...l filtering Higher filtering level is useful where noise occurs causing the reader to malfunction State inspections Key hold down Some functions can be run by the users without having to enter the cod...

Страница 14: ...ir state will be displayed in the first Us Code arrow Code arrows you can define which functions will be started on entering the code and pressing the selected arrow key Zone state Zone characters You...

Страница 15: ...u can select the function executed after holding the card Door Door to open if presenting the card or holding it is to open a door you must indicate the door supervised by the access control module or...

Страница 16: ...e alarm system In order to enter the active mode press any key on the keypad In addition to starting the active mode pressing a key will also have other consequences as appropriate for the given key T...

Отзывы: